Article View: comp.sys.dec
Article #2939Second RD54 in MVII
From: Craig Suhadolnik
Date: Sat, 29 Dec 1990 21:06
Date: Sat, 29 Dec 1990 21:06
13 lines
958 bytes
958 bytes
The solution to running a second RD54 in a MVII, concerning write protection etc, is to find the alternative style control panel to add to your BA23 box. These panels are included on some MVII BA23 boxes, and on some MicroPDP BA23 boxes. The panel has a second write protect switch for the second disk. The cabling is the same, and the panel is easy to install. I did this once when I configured a MVII in a BA23 without a TK50, the second RD54 resided in the TK50 bay. Send mail if you need help finding the panel! -- Craig Suhadolnik craig@nwnexus.wa.com 206/487-3616
Technical Details
Message-ID:
<451@nwnexus.WA.COM>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!tmsoft!torsqnt!news-server.csri.toronto.edu!cs.utexas.edu!uunet!nwnexus!craigShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!mnetor!tmsoft!torsqnt!news-server.csri.toronto.edu!cs.utexas.edu!uunet!nwnexus!craig From: craig@nwnexus.WA.COM (Craig Suhadolnik) Newsgroups: comp.sys.dec Subject: Second RD54 in MVII Keywords: solution Message-ID: <451@nwnexus.WA.COM> Date: 29 Dec 90 21:06:42 GMT Organization: Northwest Nexus Inc.; Seattle, WA Lines: 13