🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.sys.dec
Article #4029

VAXstation 3100: Incomplete Modem Control

#4029
From: Woody Muller
Date: Mon, 03 Jun 1991 18:51
14 lines
1258 bytes
I'm trying to set up a VAXstation 3100 as a satellite node in a wide-area
network.  I have found, much to my consternation, that the funny little
six-wire DEC proprietary async-communication port does not support
full modem control -- I cannot detect carrier drop and am having problems
controlling hangup on the dialup line.  We're trying to set up a dynamic
DECNET line on a dialup phone connection.  It works pretty well, except that
the end-user will have to occasionally manually hang up the modem.

Has anybody out there encountered or solved this problem?  What in the
world did DEC think it was doing when it failed to design full modem
control into the VAXstation 3100's?  It even says it right there in the
I/O User's Guide -- VAXstation 3100s cannot detect hangup.

What ever happened to standards?  RS-232 is pretty basic stuff.
Technical Details
Message-ID: <3862@bdrc.bdrc.bd.com>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!rpi!zaphod.mps.ohio-state.edu!wuarchive!cs.utexas.edu!sun-barr!newstop!sun!amdcad!dgcad!dg-rtp!bdrc!woody

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!rpi!zaphod.mps.ohio-state.edu!wuarchive!cs.utexas.edu!sun-barr!newstop!sun!amdcad!dgcad!dg-rtp!bdrc!woody
From: woody@bdrc.bd.com (Woody Muller)
Newsgroups: comp.sys.dec
Subject: VAXstation 3100: Incomplete Modem Control
Message-ID: <3862@bdrc.bdrc.bd.com>
Date: 3 Jun 91 18:51:48 GMT
Organization: Becton Dickinson Rsrch Cntr, RTP, NC
Lines: 13