wijkstra@fwi.uva.nl (Marcel Wijkstra (AIO)) writes:

> Hi,
> 
> I have a rather strange modem problem: I have a 1200 baud Hayes compat.
> modem (Repko M2000trio) that I want to connect to my 386 clone.
> I got it from a friend, who used it with a PS/2 and Procomm 2.3, which
> worked ok.
> However, when I attach it to my 386 with Procomm 2.4.2, it does not dial
> any phone number properly: I can hear the (phone) dialing tone through
> the internal speaker, waiting for a number to be dialed. But the dialing
> itself is just a short period of (fluctiating) noise (which length is
> proportional to the length of the phone number, so it DOES try to dial
> something). And then of course, nothing happens.
> With my friend's PS/2, everything still works, i.e. we can hear the
> dialing pulses.
> I've tried it with a 286 (Bull Micral, so no cheap clone...), but I get
> the same negative result. Also, I've tried using Windows' (3.0 and 3.1)
> Terminal program, but again: no luck.
> 
> What could cause this problem? I don't suppose it's the serial cable,
> since it is a full 25-wire one (or is it wrong to connect all 25 pins???)
> 
> Any help would be greatly appreciated.
> 
Bad news...  guess what.  If it came from a PS/2 and it is an internal modem
it might be a MCA modem.  If it is an external, and you type AT, and get
OK back, the cable is just fine.  I run 25 pin cable straight though on
my modems.

Do   ATS11?   and ATS9?
One of these are going to be 55 or above. (I think it will be 11, so check
that first).  Do this : ATS11=95

That will lengthen the tones to 95 ms.

Also, try ATDP and see if it pulse dials and can make it out.

Those are my ideas.

Greg

.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.
.   TCS Consulting Services   P.O. Box 600008   St. Paul, MN  55106-0008    .
.   ..!srcsip!tcscs!zeta                 ..!src.honeywell.com!tcscs!zeta    .
.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.-=-.
Technical Details
Message-ID: <VHXuwB3w165w@tcscs.UUCP>
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!howland.reston.ans.net!sol.ctr.columbia.edu!src.honeywell.com!tcscs!zeta
References: <1993Jan4.102518.10862@fwi.uva.nl>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!zaphod.mps.ohio-state.edu!howland.reston.ans.net!sol.ctr.columbia.edu!src.honeywell.com!tcscs!zeta
From: tcscs!zeta@src.honeywell.com (Gregory Youngblood)
Newsgroups: comp.sys.ibm.pc.hardware
Subject: Re: Modem dialing problem
Message-ID: <VHXuwB3w165w@tcscs.UUCP>
Date: Mon, 04 Jan 93 09:45:06 CST
References: <1993Jan4.102518.10862@fwi.uva.nl>
Reply-To: zeta%tcscs@src.honeywell.com
Organization: TCS Consulting Services
Lines: 46