Article #20562Re: Power spikes cause server crash
From: Brian Mesken
Date: Fri, 25 Oct 1991 09:01
Date: Fri, 25 Oct 1991 09:01
66 lines
3448 bytes
3448 bytes
josephc@cco.caltech.edu (Joseph Chiu) writes: >s41758@zeus.usq.EDU.AU (Brian Mesken) writes: >>I have a server (486) running 3Com's 3+Open connected to two Epson DFX- >> . >> . >> . >>Has anyone else had these type of problem? >>Any suggestion on how to solve this problem? >Hmm, seems to me like there is an e-potential difference causing problems... >As a test, I'd suggest trying these cases: > Disconnect Printer entirely from System, except for the power. > Connect Printer to System, power Printer via Power Conditioner. This one I havn't tried yet. > Similarly, connect Printer to System, power Printer by a separate > supply-line circuit. This I have tried both from a seperate supply circuit and from the same circuit, both have had the same effect. > Ensure Common Ground between System and Printer. In fact, make sure > that the two are grounded via the Parallel Printer Cable. This was the case, the chassis were connected together via the printer cables I was advised to remove this as it may be causing an earth loop. It is now disconnected. I have the system and the printers connected to the same circuit, to also eliminate the earth loop. > (Far shot) Move Printer far away from the System, but using the same > supply-line circuit. I have them close together because of the length of the printer cable, but i assume you mean far away electrically, I could try one to another circuit. > >Another remote possibility is that the Server System's power supply is >operating at limit (i.e., marginal) and that the spikes are enough to >deprive the CPU of needed power. (Remember, it only takes 1 bad opcode >taking less than ~100ns to crash.) Yes, this could be part of my problem, the power supply is up around 255 volts, which is at the upper limit of the 240 volts +/- 6%. I have requested the supply be reduced, no action yet. >Could the other spikes you mention be a result of, say, an air conditioner? >Out here at the Caltech Campus, all major computing rooms have conditioned >power going into the machines with individually filtered (passively) outlets. I expect you are correct, but I havn't been able to prove that it is the air conditioners causing spikes. I mean switching the air conditioners off on off etc. have not showed any measurable spikes. Thanks for the advice. -- Brian Mesken mesken@zeus.usq.edu.au Computer Services Unit, University College of Southern Queensland, Toowoomba, Queensland, Australia.
Technical Details
Message-ID:
<s41758.688381262@zeus>Path:
arc1-ca.pugleaf.net!gmdzi!zeus.ieee.org!europa.asd.contel.com!darwin.sura.net!gatech!ncar!elroy.jpl.nasa.gov!sdd.hp.com!spool.mu.edu!munnari.oz.au!bunyip.cc.uq.oz.au!zeus!s41758References:
<s41758.688125271@zeus> <1991Oct22.050624.1633@cco.caltech.edu>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: ffec8,ab057e90cd32334c X-Google-Attributes: gidffec8,public X-Google-Thread: 10d683,ab057e90cd32334c X-Google-Attributes: gid10d683,public X-Google-Thread: f53ba,ab057e90cd32334c X-Google-Attributes: gidf53ba,public X-Google-ArrivalTime: 1991-10-26 16:02:49 PST Path: arc1-ca.pugleaf.net!gmdzi!zeus.ieee.org!europa.asd.contel.com!darwin.sura.net!gatech!ncar!elroy.jpl.nasa.gov!sdd.hp.com!spool.mu.edu!munnari.oz.au!bunyip.cc.uq.oz.au!zeus!s41758 From: s41758@zeus.usq.EDU.AU (Brian Mesken) Newsgroups: comp.sys.ibm.pc.hardware,comp.sys.ibm.pc.misc,aus.computers.ibm-pc Subject: Re: Power spikes cause server crash Keywords: power spikes server failure Message-ID: <s41758.688381262@zeus> Date: 25 Oct 91 09:01:02 GMT References: <s41758.688125271@zeus> <1991Oct22.050624.1633@cco.caltech.edu> Lines: 66