Article View: comp.sys.ibm.pc.misc
Article #6487Re: Peltier effect device
From: Dave Pierson
Date: Fri, 28 Dec 1990 22:19
Date: Fri, 28 Dec 1990 22:19
40 lines
2374 bytes
2374 bytes
In article <6792@bgsuvax.UUCP>, valdes@bgsuvax.UUCP (oscar Valdes) writes,
in part:
> Check again. You don't need two junctions to make a thermocouple.
>Heating a single junction will produce a voltage that depends on the
>temperature of the junction.
There are always two junctions. One may be the juction of the
TC leads with the measuring instrument terminals. TC rigs always
measure the difference between the two junction temperatures. To get
an "absolute" reading, the temperature of one junction is measured
by independent means. In "lab" TCs, this is typically an RTD type
detector, mounted on a comon thermal mass with the screw terminals.
The terminal block temp is then "added" either analog fashionm, or
digitally. TCs are non linear over large delta t's, but reasonably
linear over small ones.
TCs are perfectly happy as either voltage or current output devices.
Current (8)>>) practice treats them as voltage sources, due to the
availability of good, hiZ amps. In the past, the were commonly used
with microammeters. (Hi precision work used manually or automatically
balanced bridges, which is voltage source mode.)
(attempted graphics, Cu/Con couple...)
_______Cu_____________o_(Cu)____>Amp hi
/ |
/measuring junction |<-Ref temp
\ |
\______Con_____________o__(Cu)___>Amp Lo
^-the "other" junction
(As i write this, i sit next to a logger with 16 TCs on it...)
thanks
dave pierson |the facts, as accurately as i can manage,
Digital Equipment Corporation |the opinions, my own.
600 Nickerson Rd
Marlboro, Mass
01752 pierson@cimnet.enet.dec.com
"He has read everything, and, to his credit, written nothing." A J Raffles
Technical Details
Message-ID:
<18522@shlump.nac.dec.com>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!snorkelwacker.mit.edu!bloom-beacon!deccrl!news.crl.dec.com!pa.dec.com!shlump.nac.dec.com!ggone.enet.dec.com!piersonShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!snorkelwacker.mit.edu!bloom-beacon!deccrl!news.crl.dec.com!pa.dec.com!shlump.nac.dec.com!ggone.enet.dec.com!pierson From: pierson@ggone.enet.dec.com (Dave Pierson) Newsgroups: comp.sys.ibm.pc.misc,sci.electronics Subject: Re: Peltier effect device Summary: two junctions Keywords: Thermocouples Message-ID: <18522@shlump.nac.dec.com> Date: 28 Dec 90 22:19:38 GMT Sender: newsdaemon@shlump.nac.dec.com Followup-To: comp.sys.ibm.pc.misc Organization: Digital Equipment Corporation Lines: 40