Re: needing pts's enabled to telnet INTO an RT:

We have pts0-3 autoenabled, and #'s 4-8 NOT autoenabled and starting 2
days ago we could have 8 telnets logged in at once (Okay, I only did 6,
but close enough, huh?). 

The thing we changed 2 days ago was the number of processes able to run
on the machine at a time.  In /etc/master the limit was set at 60!  Ugh!
When we boot, all the daemons, etc. total ~40 processes before anyone
is logged in!  Noticing the warning limit is 350, I upped the total to
150 (after that I expect the machine to be VERY slow) and left the
per-user process limit at 100.

Is 'procs = 60' really the default for an RT?

Perhaps this will help you use more pts's.

May all you programs compile on the first attempt.

Edward A. Silverstein
silver@director.beckman.uiuc.edu
Technical Details
Message-ID: <213600008@s.cs.uiuc.edu>
Path: arc1-ca.pugleaf.net!utzoo!yunexus!ists!jarvis.csri.toronto.edu!mailrus!cs.utexas.edu!uwm.edu!ux1.cso.uiuc.edu!ux1.cso.uiuc.edu!m.cs.uiuc.edu!s.cs.uiuc.edu!silver
References: <16994@uhnix1.uh.edu>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!yunexus!ists!jarvis.csri.toronto.edu!mailrus!cs.utexas.edu!uwm.edu!ux1.cso.uiuc.edu!ux1.cso.uiuc.edu!m.cs.uiuc.edu!s.cs.uiuc.edu!silver
From: silver@s.cs.uiuc.edu
Newsgroups: comp.sys.ibm.pc.rt
Subject: Re: TCP/IP, telnet and the RT...
Message-ID: <213600008@s.cs.uiuc.edu>
Date: 18 Nov 89 17:38:35 GMT
Article-I.D.: s.213600008
References: <16994@uhnix1.uh.edu>
Lines: 22
Nf-ID: #R:uhnix1.uh.edu:16994:s.cs.uiuc.edu:213600008:000:802
Nf-From: s.cs.uiuc.edu!silver    Nov 17 11:57:00 1989