In article <1667@ucqais.uc.edu> rainwatr@ucqais.uc.edu (Donald J. Rainwater) writes:
>When the RT is started, it tries to configure the ethernet device (net0).
>After a period of time, I get a console message saying that net0 has timed
>out, and that the device has been removed from the configuration.

Could it be that the jumper settings on your Baseband adapter don't
match the values given to `devices'? For some reason, the memory address
and interrupt level jumper settings on the adapter as shipped by IBM
don't match the default values used by `devices'. Being a software type,
I changed the `devices' values:
	rsa	from 80000 to 98000
	rea	from 81fff to 99fff
	brsa	from 82000 to 9a000
	brea	from 87fff to 9ffff
	il1	from 9     to 3
Hope this solves your problem.

Ge van Geldorp.
(...!uunet!hp4nl!dutrun!vlruo02 or ...!uunet!hp4nl!dutlru2!ge)
Technical Details
Message-ID: <716@dutrun.UUCP>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!ames!lll-winken!uunet!mcvax!hp4nl!dutrun!vlruo02
References: <1667@ucqais.uc.edu>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!ames!lll-winken!uunet!mcvax!hp4nl!dutrun!vlruo02
From: vlruo02@dutrun.UUCP (Ge van Geldorp)
Newsgroups: comp.sys.ibm.pc.rt,comp.os.vms
Subject: Re: Connecting IBM PC RT to Ethernet
Summary: Check configuration
Keywords: Baseband adapter, jumper settings, defaults
Message-ID: <716@dutrun.UUCP>
Date: 4 May 89 08:23:11 GMT
References: <1667@ucqais.uc.edu>
Reply-To: vlruo02@dutrun.UUCP (G.v.Geldorp)
Organization: Delft University of Technology, The Netherlands
Lines: 19