Re: X-RAYS and color monitors!

#25724
From: berger
Date: Thu, 17 Mar 1988 22:15
15 lines
1050 bytes
The x-rays are a result of the second anode voltage - in the
neighborhood of 20,000 volts.  Most of the internal adjustments
will NOT affect that.  I don't think I've seen a color monitor
from the factory (any brand) in the past 5 years that didn't
need to be converged - that's a routine service adjustment, and
it won't affect the radiation levels from the CRT.

			Mike Berger
			Department of Statistics 
			Science, Technology, and Society
			University of Illinois 

			berger@clio.las.uiuc.edu
			{ihnp4 | convex | pur-ee}!uiucuxc!clio!berger