🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.sys.ibm.pc
Article #26471

Re: Question about hard disk interleave factors

#26471
From: Vince Skahan
Date: Fri, 15 Apr 1988 11:42
13 lines
1173 bytes
I have a Tandy 20MB hard card that came with a recommended
interleave factor of 3.  The guy at the Radio Shack Computer
Center said they'd done extensive local testing and recomended
using 2.

I tested it myself and found "4" was the answer (giving a 450%
increase in speed over both of the Tandy-recommended settings).
Unfortunately, I believed them for 6 months and had to live with 
the slow speed until I had time to test different settings myself.
-- 
     Vince Skahan            Boeing Computer Services - Phila.
    (215) 591-4116           INTERNET:  bcs212%psev@boeing.com
UUCP: {...rutgers!bpa | uw-beaver!uw-june!bcsaic}!vader!bcs212 
Technical Details
Message-ID: <188@vader.UUCP>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!water!watmath!clyde!att-cb!osu-cis!tut.cis.ohio-state.edu!bloom-beacon!mit-eddie!uw-beaver!ssc-vax!bcsaic!vader!bcs212
References: <2832@dalcs.UUCP>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!water!watmath!clyde!att-cb!osu-cis!tut.cis.ohio-state.edu!bloom-beacon!mit-eddie!uw-beaver!ssc-vax!bcsaic!vader!bcs212
From: bcs212@vader.UUCP (Vince Skahan)
Newsgroups: comp.sys.ibm.pc
Subject: Re: Question about hard disk interleave factors
Keywords: fixed disk interleave
Message-ID: <188@vader.UUCP>
Date: 15 Apr 88 11:42:27 GMT
References: <2832@dalcs.UUCP>
Reply-To: bcs212@vader.UUCP (Vince Skahan)
Distribution: na
Organization: Boeing Computer Services - Phila.
Lines: 13