I have a Tandy 20MB hard card that came with a recommended
interleave factor of 3. The guy at the Radio Shack Computer
Center said they'd done extensive local testing and recomended
using 2.
I tested it myself and found "4" was the answer (giving a 450%
increase in speed over both of the Tandy-recommended settings).
Unfortunately, I believed them for 6 months and had to live with
the slow speed until I had time to test different settings myself.
--
Vince Skahan Boeing Computer Services - Phila.
(215) 591-4116 INTERNET: bcs212%psev@boeing.com
UUCP: {...rutgers!bpa | uw-beaver!uw-june!bcsaic}!vader!bcs212
Technical Details
Message-ID:
<188@vader.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!water!watmath!clyde!att-cb!osu-cis!tut.cis.ohio-state.edu!bloom-beacon!mit-eddie!uw-beaver!ssc-vax!bcsaic!vader!bcs212References:
<2832@dalcs.UUCP>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!water!watmath!clyde!att-cb!osu-cis!tut.cis.ohio-state.edu!bloom-beacon!mit-eddie!uw-beaver!ssc-vax!bcsaic!vader!bcs212 From: bcs212@vader.UUCP (Vince Skahan) Newsgroups: comp.sys.ibm.pc Subject: Re: Question about hard disk interleave factors Keywords: fixed disk interleave Message-ID: <188@vader.UUCP> Date: 15 Apr 88 11:42:27 GMT References: <2832@dalcs.UUCP> Reply-To: bcs212@vader.UUCP (Vince Skahan) Distribution: na Organization: Boeing Computer Services - Phila. Lines: 13