Re: low leakage "AT" power supply

#26662
From: Bill Mayhew
Date: Sat, 23 Apr 1988 20:34
11 lines
890 bytes
I am not aware of an AT power supply that meets low leakage
standars.  It seems that perhaps the most pragmatic solution would
be to purchase an ultra isolation transformer that has a 1:1 turns
ratio.  The offending AT can then be plugged into the transformer.
Companies such as Sola and Topaz, to name only a few, make such
devices.  Unfortunately, isolation transformers aren't usually
inexpensive.


--Bill