Re: Procomm Plus Problems

#7955
From: CHRISTER OLSSON
Date: Sat, 02 Dec 1989 19:06
13 lines
1062 bytes
In article <5690@ncrwic.Wichita.NCR.COM>, mregeste@ncrwic.Wichita.NCR.COM
> (Mark Regester) writes: 
> Autoexec.bat loads a memory resident program and then later in the
> batch file, creates an environment variable like "set temp=c:\temp".
> 
> Again Procomm Plus aborts with the ".DIR" message.  If the environment
> variables are set before the memroy resident program, there are
> no error messages.
> 
> Any ideas on what is happening here?
The memory resident program perhaps create a new environment with the
old variables but sets the size to so small that you can't get room 
for pcplus after setting TEMP=C:\TEMP. 
Technical Details
Message-ID: <4370@tekno.chalmers.se>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!ames!think!samsung!uunet!mcsun!sunic!chalmers!tekno.chalmers.se!cth_co
References: <5690@ncrwic.Wichita.NCR.COM>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!ames!think!samsung!uunet!mcsun!sunic!chalmers!tekno.chalmers.se!cth_co
From: cth_co@tekno.chalmers.se (CHRISTER OLSSON)
Newsgroups: comp.sys.ibm.pc
Subject: Re: Procomm Plus Problems
Message-ID: <4370@tekno.chalmers.se>
Date: 2 Dec 89 19:06:40 GMT
References: <5690@ncrwic.Wichita.NCR.COM>
Organization: Chalmers Univ. of Technology, Gothenburg, Sweden
Lines: 13