Article View: comp.sys.mac
Article #13638Re: Mac+ DTR upside down?
From: Peter Horan
Date: Thu, 27 Nov 1986 04:48
Date: Thu, 27 Nov 1986 04:48
22 lines
1407 bytes
1407 bytes
In article <3897@nsc.NSC.COM> curry@nsc.UUCP (Ray Curry) writes:
>Don't forget that the rs232/rs422 world defines their signals as active (DTR)
>but the lines are all physical (DTR-). DTR- line being held low is active.
This is not correct for control lines like DTR.
From the standard EIA RS232C Aug 1969:
Notation Interchange Voltage
Negative Positive
Binary State 1 0
Signal Condition Marking Spacing {the data lines}
Function OFF ON {lines like DTR}
So data lines are negative logic, whereas control lines are positive
logic.
Peter Horan ACSnet: peter@aragorn.oz
Division of Computing and Mathematics UUCP: {seismo,ukc,mcvax}!munnari!
Deakin University aragorn!peter
Geelong ARPA: peter%aragorn.oz@seismo.edu.gov
Victoria +61 52 471234
Australia 3217 (052) 471234
Technical Details
Message-ID:
<298@aragorn.OZ>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!seismo!munnari!mulga!charlie!aragorn!peterReferences:
<1372@umd5> <3897@nsc.NSC.COM>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!mnetor!seismo!munnari!mulga!charlie!aragorn!peter From: peter@aragorn.OZ (Peter Horan) Newsgroups: comp.sys.mac Subject: Re: Mac+ DTR upside down? Message-ID: <298@aragorn.OZ> Date: Wed, 26-Nov-86 23:48:58 EST Article-I.D.: aragorn.298 Posted: Wed Nov 26 23:48:58 1986 Date-Received: Thu, 27-Nov-86 07:59:16 EST References: <1372@umd5> <3897@nsc.NSC.COM> Reply-To: peter@aragorn.UUCP (Peter Horan) Distribution: net Organization: Division of Comp/Maths, Deakin Uni., Australia Lines: 22