Article View: comp.sys.mac
Article #3943Re: SCSI termination problem-really wierd!
From: Ed Burress
Date: Sat, 02 Sep 1989 00:49
Date: Sat, 02 Sep 1989 00:49
56 lines
2896 bytes
2896 bytes
> Unless the new disk is turned on, my system will just flash the 'waiting for
> a disk to boot' question mark.
> But for some reason HD#2 must be ON for the system to work....
> Any ideas?
>
> Phil Hunt
Your problem may be that the SCSI termination power on pin 25 of the external
SCSI connector is not being provided. The power is provided through a 1 Amp
fuse which may have opened due to "hot plugging", excessive loading, or
accidental shorting of this supply to ground (which they provide at pin 24).
I've looked at this problem here in my own group, as well as several places
in our company, and found this the the root of the cause for the problem you
have described in every case. Since you have so many devices hooked to the
SCSI bus, it could be that the supply is being loaded down sufficiently to
cause the same symptoms, but I doubt this is the case. If your Mac is still
under warranty, take it in to have the SCSI termination power checked. If
your Mac has no warranty, and you feel comfortable with the idea of testing
your Mac yourself, then heres a little help:
To find out if your SCSI fuse has been blown, probe pin 24, and 25 of the
external connector with a volt meter, if it shows 5 volts DC, then the fuse is
not the problem.
WARNING: BE ESPECIALLY CAREFUL NOT TO SHORT THE PINS TOGETHER WHILE MEASURING,
OR YOU *WILL* SNUFF THE FUSE.
After inspection, if the fuse has been found to be bad, there are three things
you may do:
1. Pay an authorized apple service center $429 to have the board replaced
( no they don't replace the fuse )
2. Throw the Mac away.
3. Replace the fuse yourself ( only if you can use a soldering iron, yes
they solder them in so that they can get you to do #1 or #2 above.)
If you opt for #3 as I did, the fuse is located near the rear of the macintosh , under the disk shelf, and hidden under a ribbon cable, it's labeled F1.
I hope this helps.....but if you screw-up, remember, you're on your own.
--------------------------------------------------------------
U.S. Mail: edbu@pogo
Ed Burress 63-356 Phone (503)-685-3200
Tektronix, Inc.
PO box 500 Beaverton, Oregon,
97077
--------------------------------------------------------------
"A wise monkey never monkeys with another monkey's monkey."
--------------------------------------------------------------
Technical Details
Message-ID:
<7816@pogo.WV.TEK.COM>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!csd4.csd.uwm.edu!cs.utexas.edu!uunet!zephyr.ens.tek.com!orca!pogo!edbuReferences:
<8909011634.AA28632@decwrl.dec.com>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!csd4.csd.uwm.edu!cs.utexas.edu!uunet!zephyr.ens.tek.com!orca!pogo!edbu From: edbu@pogo.WV.TEK.COM (Ed Burress) Newsgroups: comp.sys.mac Subject: Re: SCSI termination problem-really wierd! Summary: SCSI termination power on pin 25 ? Message-ID: <7816@pogo.WV.TEK.COM> Date: 2 Sep 89 00:49:11 GMT References: <8909011634.AA28632@decwrl.dec.com> Organization: Tektronix Inc., Beaverton, Or. Lines: 56