🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.sys.mac
Article #40178

Re: Serial Cable Length Limitations

#40178
From: Rick Klaus
Date: Fri, 31 Mar 1989 19:09
11 lines
896 bytes
     The Mac / Imagewriter II interface is RS422 rather than RS232.  As such
you should be able to run a cable (at the 9600 baud IW speed) nearly a mile
long.  The differential nature of the data lines should help cancel the
RF effects which you are worried about.  The handshake line is not
differential, but due to the low speed of signals on this line, you should
be able to run several thousand feet without any problems.

Rick Klaus
HP Vancouver
rickk@hpvcfs1.hp.com
Technical Details
Message-ID: <780002@hpvcfs1.HP.COM>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!tut.cis.ohio-state.edu!ucbvax!ucsd!sdcsvax!ucsdhub!hp-sdd!hplabs!hp-pcd!hpvcfs1!rickk
References: <6807@saturn.ucsc.edu>

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!tut.cis.ohio-state.edu!ucbvax!ucsd!sdcsvax!ucsdhub!hp-sdd!hplabs!hp-pcd!hpvcfs1!rickk
From: rickk@hpvcfs1.HP.COM (Rick Klaus)
Newsgroups: comp.sys.mac
Subject: Re: Serial Cable Length Limitations
Message-ID: <780002@hpvcfs1.HP.COM>
Date: 31 Mar 89 19:09:40 GMT
References: <6807@saturn.ucsc.edu>
Organization: Hewlett Packard, Vancouver, WA
Lines: 11