Re: SCIS-2 & FastSCSI

#51
From: Barry Lustig
Date: Thu, 29 Oct 1992 02:42
22 lines
967 bytes
In article <1992Oct28.222856.168@pyrian.com> ian@pyrian.com (Ian H. Stewart) writes:
	What is the difference between these two.
	
	My understanding is that FastSCSI has a trans rate of
	10MB/sec.
	
	At one time I was told they were the same, but the
	my NeXT uses SCSI-2 and it only transfers at something
	like 5MB/sec
	
	Any help is appreciated.
	
SCSI-2 runs at 5MB/sec.  SCSI-2 FAST runs at 10MB/sec.  SCSI-2 FAST &
wide runs at 20MB/sec.  SCSI-2 FAST & double wide runs at 40MB/sec.
The NeXT has a SCSI-2 *connector* on the back.  It is running its bus
at 5.

barry



-- 