Hi,
For some reason when you do a rlogin, the rlogind on the other side does
not set your controlling tty. This can be repeated by any user with /bin/sh as
login shell :
$ rlogin <some machine>
..
$ tty
/dev/ttyp0
$ echo hello > /dev/tty
/dev/tty: cannot create
$ ls -l /dev/tty
crw-rw-rw- 1 root 2, 0 Jul 30 22:50 /dev/tty
$
The actual error (errno) is not "cannot create" but :
$ csh
machine-name> echo hello > /dev/tty
/dev/tty: No such device or address
machine-name> exit
$ ps -l $$
F UID PID PPID CP PRI BASE VSIZE RSIZE WCHAN STAT TT TIME COMMAND
1 32 1150 1148 0 10 10 8.64M 144K 0 S ? 0:00 -sh (sh)
^^^
$
e.g. no controlling tty. You can acquire one because the first terminal
you open will become you controlling tty.
$ echo hello > `tty`
hello
$ echo hello > /dev/tty
hello
$
For /bin/sh this is no big problem just add "echo -n > `tty`" to
your .profile . But tcsh will refuse to acquire a new controlling tty
(which is ofcourse correct).
This happens in both NS 2.x and NS 3.0.
This is a bug isn't it ?
--
Maarten Huisjes. mjh@cs.vu.nl (192.31.231.42)
(..!uunet.uu.net!cs.vu.nl!mjh)
Technical Details
Message-ID:
<BvEFu2.8xI@cs.vu.nl>Path:
arc1-ca.pugleaf.net!sparky!uunet!mcsun!sun4nl!star.cs.vu.nl!mjhShow Full Headers
Complete Article Headers
Newsgroups: comp.sys.next.sysadmin,comp.sys.next.misc Path: arc1-ca.pugleaf.net!sparky!uunet!mcsun!sun4nl!star.cs.vu.nl!mjh From: mjh@cs.vu.nl (Huisjes MJ) Subject: rlogin ---> no controlling tty ? (bug ?) Message-ID: <BvEFu2.8xI@cs.vu.nl> Keywords: rlogin tty Sender: news@cs.vu.nl Organization: Fac. Wiskunde & Informatica, VU, Amsterdam Date: Wed, 30 Sep 1992 16:15:38 GMT Lines: 48