Re: Wren III HH on 3/50 gets SCSI bus failure every 2-3 days?

#11982
From: Mike Ubell
Date: Fri, 07 Apr 1989 15:10
10 lines
1158 bytes
In article <8903160104.AA23007@rocket.sanders.com>:
>We have had the disk (~90 Mbyte) on a 3/50 to page on for several months,
>but I just fixed a boo-boo in /usr/adm/ that prevented messages.  Now I
>see that every few days we have a crash scsi-bus failure, i/o error in
>swap....

We had a similar problem.  Remapping the sector cleared the problem.  I
don't think you can do it with the standard SUN diag program but we got
our drives from a third party and it came with software to do it.
(Running 3.2 the system just hangs rather than reporting the error.)
Technical Details
Message-ID: <8903310044.AA13509@blipyramid.BLI.COM>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!tut.cis.ohio-state.edu!ucbvax!husc6!rice!sun-spots-request

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!tut.cis.ohio-state.edu!ucbvax!husc6!rice!sun-spots-request
From: blia!blipyramid!mike@uunet.uu.net (Mike Ubell)
Newsgroups: comp.sys.sun
Subject: Re: Wren III HH on 3/50 gets SCSI bus failure every 2-3 days?
Keywords: SunOS
Message-ID: <8903310044.AA13509@blipyramid.BLI.COM>
Date: 7 Apr 89 15:10:10 GMT
Sender: usenet@rice.edu
Organization: Britton Lee
Lines: 10
Approved: Sun-Spots@rice.edu
Original-Date: Thu, 30 Mar 89 16:44:34 PST
X-Sun-Spots-Digest: Volume 7, Issue 229, message 11 of 15
X-Issue-Reference: v7n215