Some weeks ago I asked for help regarding an annoying frreze up of my 386i
every few minutes. Here's a summary of the replies:
The Ethernet controller has a bug, such that if it is connected to a
network with no traffic for 240 or 255 seconds, it resets itself,
resulting in no screen output for 4 or 5 seconds. This annoying bug does
not show up if the system is on a busy Ethernet or has networking
disabled. Sun are working on a fix. If you have two or more workstations
on the network, you can make them ping each other every four minutes or
less to prevent the freeze-up. A 386i ith a couple of lightly-used PC's on
its network is outa luck until Sun fixes the bug.
Stefan W. Mochnacki INTERNET - stefan@helios.physics.toronto.edu
Astronomy, U. Toronto UUCP - {uunet,pyramid}!utai!helios!stefan
+1 (416) 884-9562 BITNET - mochnacki@utorphys.bitnet
Technical Details
Message-ID:
<8903310556.AA10674@helios.physics.utoronto.ca>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!cornell!uw-beaver!rice!sun-spots-requestShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!cornell!uw-beaver!rice!sun-spots-request From: stefan@helios.physics.utoronto.ca (Stefan Mochnacki) Newsgroups: comp.sys.sun Subject: Re: Sun 386i screen freezing problem Keywords: 386i Message-ID: <8903310556.AA10674@helios.physics.utoronto.ca> Date: 21 Apr 89 00:51:20 GMT Sender: usenet@rice.edu Organization: Sun-Spots Lines: 15 Approved: Sun-Spots@rice.edu Original-Date: Fri, 31 Mar 89 00:56:53 EST X-Sun-Spots-Digest: Volume 7, Issue 232, message 8 of 21