Article View: comp.sys.sun
Article #12347solution: Wren III HH on 3/50 gets SCSI bus failure every 2-3 days
From: Webster Dove
Date: Thu, 27 Apr 1989 06:03
Date: Thu, 27 Apr 1989 06:03
5 lines
755 bytes
755 bytes
The cable in the drive was resting against the PC board in the back of the drive. It had softened due to heat and was intermittantly shorting out (I suspect). Replacing the cable fixed the problem. Web
Technical Details
Message-ID:
<8904120251.AA24543@rocket.sanders.com>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!bbn!mit-eddie!uw-beaver!rice!sun-spots-requestShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!bbn!mit-eddie!uw-beaver!rice!sun-spots-request From: rocket!dove@uunet.uu.net (Webster Dove) Newsgroups: comp.sys.sun Subject: solution: Wren III HH on 3/50 gets SCSI bus failure every 2-3 days Keywords: Hardware Message-ID: <8904120251.AA24543@rocket.sanders.com> Date: 27 Apr 89 06:03:24 GMT Sender: usenet@rice.edu Organization: Sun-Spots Lines: 5 Approved: Sun-Spots@rice.edu Original-Date: Tue, 11 Apr 89 22:51:43 EDT X-Sun-Spots-Digest: Volume 7, Issue 257, message 8 of 16