If you have a 3/460, 3/470, 3/480, you should note an error in:
Sun 3400 CPU Board Configuration Manual
(PN 813-2055-11, Rev A 15 May 1989)
The 3-4 jumper in J2100 (at N-19 on the board), should be IN and should be
factory installed that way. (In the manual, it says this jumper is
reserved, should be OUT and is factory installed that way.) If it's not
in, the CPU board will be happy and pass all self-tests, but won't find
a SMD4 controller.
Ted Kim
UCLA Computer Science Department Internet: tek@penzance.cs.ucla.edu
3804C Boelter Hall UUCP: ...!{uunet|ucbvax}!cs.ucla.edu!tek
Los Angeles, CA 90024 Phone: (213) 206-8696
Technical Details
Message-ID:
<4489@brazos.Rice.edu>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!cs.utexas.edu!rice!sun-spots-requestShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!mailrus!cs.utexas.edu!rice!sun-spots-request From: tek@cs.ucla.edu (Ted Kim (Random Dude)) Newsgroups: comp.sys.sun Subject: jumpers Keywords: Hardware Message-ID: <4489@brazos.Rice.edu> Date: 27 Jan 90 20:42:33 GMT Sender: root@rice.edu Organization: Sun-Spots Lines: 15 Approved: Sun-Spots@rice.edu X-Sun-Spots-Digest: Volume 9, Issue 14, message 13 of 14