Broadcast Storms on Ethernet

#13764
From: Martin Holland
Date: Tue, 13 Feb 1990 18:57
16 lines
1360 bytes
We have three ethernet cables here. One main backbone and two smaller
networks. Each smaller network is joined to the main backbone by a SUN
workstation with two ethernet cards in it. We use subnetting with a mask
of 255.255.255.0.  We have found that if any UNIX node on the main
backbone sends a broadcast, usually from a RWHO daemon it causes the SUN
gateways to send a storm of broadcasts onto the network each containing
the nodename of the node that sent the origional broadcast.  These storms
cause the ethernet performance to degrade badly.  Is there anything we can
to stop the gateway nodes from sending broadcast storms.  These storms
only origionate from gateway machines, other SUN workstations on the main
backbone are unaffected.

Martin C. Holland       Internal e/mail: HOLLANDM@PHIRHV1
Philips Research Labs.  External e/mail: HOLLANDM@prl.philips.co.uk
Redhill, Surrey. U.K.
Tel: 0293 785544 X 5911 
Technical Details
Message-ID: <4957@brazos.Rice.edu>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!cs.utexas.edu!rice!sun-spots-request

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!jarvis.csri.toronto.edu!cs.utexas.edu!rice!sun-spots-request
From: hollandm@prl.philips.co.uk (Martin Holland)
Newsgroups: comp.sys.sun
Subject: Broadcast Storms on Ethernet
Keywords: Networks
Message-ID: <4957@brazos.Rice.edu>
Date: 13 Feb 90 18:57:13 GMT
Sender: root@rice.edu
Organization: Sun-Spots
Lines: 16
Approved: Sun-Spots@rice.edu
X-Sun-Spots-Digest: Volume 9, Issue 33, message 10