With reference to Len Moskowitz's posting:-
> One of our constraints is that the final system must occupy no more
> than three 6U VME slots. Both Inmos and Transtech have 6U boards (the
> B014 and the MCP500 respectively) that accommodate eight size-1
> transputer modules ("TRAMS")
Len -- You can't stack a populated B014-style motherboard on 0.8-inch
centres. They just don't go. You might get away with 1.2-inch centres
if you have a REALLY GOOD airflow (e.g. fans above and below) but
otherwise you'll need 1.6-inch centres. Believe me: we've been there!
Chris Brown, A.I. Vision Research Unit, Sheffield University
(chris@aivru.sheffield.ac.uk)
Technical Details
Message-ID:
<9010151443.AA05943@aivru.uucp>Path:
arc1-ca.pugleaf.net!utzoo!attcan!uunet!wuarchive!usc!ucsd!dog.ee.lbl.gov!pasteur!ucbvax!aivru.sheffield.ac.uk!chrisShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!attcan!uunet!wuarchive!usc!ucsd!dog.ee.lbl.gov!pasteur!ucbvax!aivru.sheffield.ac.uk!chris From: chris@aivru.sheffield.ac.uk (Chris Brown) Newsgroups: comp.sys.transputer Subject: Re: CLIPS benchmark Message-ID: <9010151443.AA05943@aivru.uucp> Date: 15 Oct 90 14:43:10 GMT Sender: daemon@ucbvax.BERKELEY.EDU Organization: The Internet Lines: 15