🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.sys.transputer
Article #1112

Stop Bits

#1112
From: David Boreham
Date: Tue, 20 Nov 1990 16:22
18 lines
1062 bytes
stiles@cc.usu.edu  (Dyke Stiles)  writes:

>Question: What does the link controller do if, e.g., it receives a string of
>11 or more 1's (i.e., non stop bit appears)?  Does it simply wait until
>a zero shows up and then report that it received a byte of all 1's??

The transputer does not ever check for the stop bit. 
The stop bit is transmitted for the purposes of being
able to see the start bit !

David.



David Boreham, INMOS Limited | mail(uk): davidb@inmos.co.uk or ukc!inmos!davidb
Bristol,  England            |     (us): uunet!inmos.com!davidb
+44 454 616616 ex 547        | Internet: davidb@inmos.com
Technical Details
Message-ID: <12665@ganymede.inmos.co.uk>
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!samsung!think.com!mintaka!bloom-beacon!eru!hagbard!sunic!mcsun!ukc!inmos!inmos.co.uk!davidb

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!cs.utexas.edu!usc!samsung!think.com!mintaka!bloom-beacon!eru!hagbard!sunic!mcsun!ukc!inmos!inmos.co.uk!davidb
From: davidb@inmos.co.uk (David Boreham)
Newsgroups: comp.sys.transputer
Subject: Stop Bits
Message-ID: <12665@ganymede.inmos.co.uk>
Date: 20 Nov 90 16:22:35 GMT
Sender: rob@inmos.co.uk
Reply-To: davidb@inmos.co.uk (David Boreham)
Organization: none
Lines: 18