Article View: comp.sys.transputer
Article #1247C40 to T805 Connection
From: 5140840
Date: Thu, 01 Oct 1992 13:05
Date: Thu, 01 Oct 1992 13:05
17 lines
1057 bytes
1057 bytes
In article <1992Sep22.212637.27141@allegra.att.com> of comp.sys.transputer, hgs@allegra.att.com writes: > 2) Is there a device that converts T9000 DS signals to TMS320C40 > signals, allowing interconnection between the two devices? Roger Shepherd of Inmos did a very good overview of some of the issues a designer would have to face. I do, however, know of one company that has T805s and C40s talking to one another through the Inmos Link Adapter. Specifically they take two C40 commports through the link adapter and hook up to one T805 link. Regards, Mitch Reifel Texas Instruments Houston, Texas
Technical Details
Message-ID:
<921001080544@128.247.81.82>Path:
arc1-ca.pugleaf.net!sparky!uunet!cs.utexas.edu!csc.ti.com!tilde.csc.ti.com!pan.mc.ti.com!128.247.81.82!rgammonShow Full Headers
Complete Article Headers
Newsgroups: comp.sys.transputer Path: arc1-ca.pugleaf.net!sparky!uunet!cs.utexas.edu!csc.ti.com!tilde.csc.ti.com!pan.mc.ti.com!128.247.81.82!rgammon From: 5140840@mcimail.com Subject: C40 to T805 Connection Message-ID: <921001080544@128.247.81.82> Nntp-Software: PC/TCP NNTP Lines: 17 Sender: usenet@pan.mc.ti.com (USENET News System) Organization: Texas Instruments Materials and Controls Group Date: Thu, 1 Oct 1992 13:05:44 GMT