Article View: comp.sys.zenith
Article #541Re: zenith z-19 terminal help needed
From: Dan Mandell
Date: Mon, 25 Feb 1991 13:04
Date: Mon, 25 Feb 1991 13:04
24 lines
1096 bytes
1096 bytes
I have the manual for the Z19 in front of me.
sw401:
0-3 Baud Rate
4 0=no parity, 1 = parity
5 0=odd parity, 1=even
6 0=normal parity, 1=stick parity
7 0=half duplex,1=full parity
0 is up; 1 is down
Baud 0 1 2 3
1200 1 0 1 0
2400 0 0 0 1
9600 0 0 1 1
sw402: push all switches to 0 for starters
switch 5 is 0=Zenith mode; 1 = ANSI mode
If you need other info , ask.
Dan
Dan Mandell (mandell@bach.helios.nd.edu)
Saint Mary's College, Computer Services
Notre Dame, Indiana 46556 - Phone: (219) 284-4610
Technical Details
Message-ID:
<1991Feb25.130415.6662@news.nd.edu>Path:
arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!bonnie.concordia.ca!uunet!spool.mu.edu!news.nd.edu!mozart!mandellReferences:
<4202@pluto.dss.com>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!utgpu!news-server.csri.toronto.edu!bonnie.concordia.ca!uunet!spool.mu.edu!news.nd.edu!mozart!mandell From: mandell@mozart.helios.nd.edu (Dan Mandell) Newsgroups: comp.sys.zenith Subject: Re: zenith z-19 terminal help needed Summary: Dip switch settings Keywords: dip switches Message-ID: <1991Feb25.130415.6662@news.nd.edu> Date: 25 Feb 91 13:04:15 GMT References: <4202@pluto.dss.com> Sender: mandell@bach.helios.nd.edu Organization: University of Notre Dame, Notre Dame Lines: 24