Article View: comp.terminals
Article #107Re: Resetting XON/XOFF on vt220's
From: Sean Phelan
Date: Thu, 22 Jun 1989 15:41
Date: Thu, 22 Jun 1989 15:41
27 lines
1578 bytes
1578 bytes
In article <64338@yale-celray.yale.UUCP> leichter@CS.YALE.EDU (Jerry Leichter) writes:
>In article <2196@bingvaxu.cc.binghamton.edu>, support@bingvaxu.cc.binghamton.edu (Academic Support) writes...
>>Does anyone know if it's possible to reset the flow control on a
>>vt220 terminal via some control sequence?
>>....
>>What I'd like to do is have the students' initialization file reset the
>>flow control to XON/XOFF, thus reducing the hysteria of novice users
>>...
>
>Can't be done.
> -- Jerry
Well, it can be done, but not in isolation. Why not just send a DECSTR
"Soft terminal reset" sequence ( CSI ! p ) thereby restoring the power-on
settings of the terminal ? For a really rock-solid solution, start your
initialisation with RIS, "Hard terminal reset", which is ESC c. Only
problem with that is the 1-2 second pause while the terminal does a
self-test.
Cheers,
Sean
--
Sean Phelan | "Education furnishes the mind,
Geac Computer, Markham, Ontario | making it a pleasant place to
sean@geac | spend the rest of one's life"
{uunet!mnetor,yunexus,unicus,utgpu}!geac!sean |
Technical Details
Message-ID:
<7519@geac.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!yunexus!geac!seanReferences:
<64338@yale-celray.yale.UUCP>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!yunexus!geac!sean From: sean@geac.UUCP (Sean Phelan) Newsgroups: comp.terminals Subject: Re: Resetting XON/XOFF on vt220's Message-ID: <7519@geac.UUCP> Date: 22 Jun 89 15:41:21 GMT Article-I.D.: geac.7519 References: <64338@yale-celray.yale.UUCP> Reply-To: sean@geac.UUCP (Sean Phelan) Organization: Geac Computers, Markham, Ontario Canada Lines: 27