Article #984Vt320 Xon XoffHello,
From: Philip Macdonald
Date: Thu, 05 Nov 1992 21:13
Date: Thu, 05 Nov 1992 21:13
22 lines
1313 bytes
1313 bytes
This may be a FAQ but here goes anyway. I've setup
some VT320 to talk to a DEC server. I've noticed that
when users connect to a UNIX account and run EMACS
strange things happen. The down arrow key causes the
EMACS to flip out after a few "DOWN ARROWS". I attributed
this to the XON XOFF flow control. If I set flow control
to off things work great. The problem is that when this
is set to off the "HOLD SCREEN" button and LED are disabled.
Control-S will hold the screen but not light the HOLD SCREEN
LED. Now if a user hits Control-S when they ment to hit
Shift-S the screen freezes and they are stuck.
What I need to know is:
What kind of setup do you need to talk to EMACS and IRC (for that
matter) without having Xon=OFF?
Thanks in advance,
Phil
pmacdon@husc10.harvard.edu
Technical Details
Message-ID:
<pmacdon.720998015@husc10>Path:
arc1-ca.pugleaf.net!sparky!uunet!ferkel.ucsb.edu!taco!rock!stanford.edu!agate!ames!saimiri.primate.wisc.edu!zaphod.mps.ohio-state.edu!uwm.edu!ogicse!das-news.harvard.edu!husc-news.harvard.edu!husc10!pmacdonShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!ferkel.ucsb.edu!taco!rock!stanford.edu!agate!ames!saimiri.primate.wisc.edu!zaphod.mps.ohio-state.edu!uwm.edu!ogicse!das-news.harvard.edu!husc-news.harvard.edu!husc10!pmacdon From: pmacdon@husc10.harvard.edu (Philip Macdonald) Newsgroups: comp.terminals Subject: Vt320 Xon XoffHello, Message-ID: <pmacdon.720998015@husc10> Date: 5 Nov 92 21:13:35 GMT Article-I.D.: husc10.pmacdon.720998015 Lines: 22 Nntp-Posting-Host: husc10.harvard.edu