>   ... The
>   810 has a thumbwheel switch that must be set to "3" for LocalTalk and
>   to some other number for the RS-232 port. Is changing the switch position
>   sufficient to disconnect the printer from LocalTalk and connect it to
>   RS-232 or must I also remove the LocalTalk cable from the printer?

The manual implies that when you are physically connected to AppleTalk
(I assume "LocalTalk" is synonymous), the switch must stay set to 3 at
all times.  "A mistake in the switch setting could bring down the entire
network", it says.

				Henry Spencer @ U of Toronto Zoology
				{ihnp4,decvax,uunet!mnetor}!utzoo!henry


----------------------------------------
Submissions to: desktop@plaid.sun.com
Administrivia to: desktop-request@plaid.sun.com
UUCP: {amdahl,decwrl,hplabs,ihnp4}!sun!plaid!desktop{-request}
Archives can be gotten from the archive-server.
To get information on the archive-server, send mail to:
archive-server@plaid.sun.com -or- sun!plaid!archive-server
with a subject line of help
Technical Details
Message-ID: <52129@sun.uucp>
Path: arc1-ca.pugleaf.net!utzoo!mnetor!uunet!husc6!cmcl2!nrl-cmf!ames!oliveb!sun!news

Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!mnetor!uunet!husc6!cmcl2!nrl-cmf!ames!oliveb!sun!news
From: news@sun.uucp (news)
Newsgroups: comp.text.desktop
Subject: Re: QMS PS-810
Message-ID: <52129@sun.uucp>
Date: 5 May 88 15:55:06 GMT
Distribution: comp
Organization: Sun Microsystems, Inc. - Mtn View, CA
Lines: 23
Approved: desktop-request%plaid@sun.com