🚀 go-pugleaf

RetroBBS NetNews Server

Inspired by RockSolid Light RIP Retro Guy

Article View: comp.unix
Article #497

Re: Pipes Signals Interprocess-I/O

#497
From: Andrew Klossner
Date: Thu, 14 Jan 1988 15:23
16 lines
1034 bytes
[These answers apply to Berkeley-derived Unices ...]

	"Well, the SIGIO handler works fine to detect input from places
	like stdin, but never sees anything coming down the pipe."

The man page for fcntl(2) says that SIGIO only happens for
terminal-class files.

	"Is there a way that I can determine WHICH file descriptor
	caused a SIGIO interrupt to be invoked?"

Not directly, but you can find out at any time which fd's have input
ready with select(2).
-- 
  -=- Andrew Klossner   (decvax!tektronix!tekecs!andrew)       [UUCP]
                        (andrew%tekecs.tek.com@relay.cs.net)   [ARPA]