What is the proper argument sequence to type converters? The manual says:
static Boolean CvtStringToPixel(display, args, num args, fromVal, toVal, converter data)
but the code says:
XmuCvtStringToOrientation(args, num_args, fromVal, toVal)
XrmValuePtr *args; /* unused */
Cardinal *num_args; /* unused */
XrmValuePtr fromVal;
XrmValuePtr toVal;
Which is right? Either? Neither? Both? Am I missing something somewhere?
Please send any followups to me personally by email. I usually read xpert on
comp.windows.x but our news is badly broken at UT right now. Of course you
can post followups of general interest also.
-David L. Battle
battle@battle.esd.ornl.gov
battle@utkux1.utk.edu
Technical Details
Message-ID:
<9002071619.AA03548@battle.ESD.ORNL.GOV>Path:
arc1-ca.pugleaf.net!utzoo!attcan!uunet!snorkelwacker!bloom-beacon!BATTLE.ESD.ORNL.GOV!battleShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!attcan!uunet!snorkelwacker!bloom-beacon!BATTLE.ESD.ORNL.GOV!battle From: battle@BATTLE.ESD.ORNL.GOV (David L. Battle) Newsgroups: comp.windows.x Subject: Type Conversion Procedures Message-ID: <9002071619.AA03548@battle.ESD.ORNL.GOV> Date: 7 Feb 90 16:19:39 GMT Sender: daemon@athena.mit.edu (Mr Background) Organization: The Internet Lines: 23