FA: UTC HA-107 AUDIO INTERSTAGE TRANSFORMER (Fully-Tested)

#92
From: Mark & Mary Ann Weiss
Date: Thu, 15 Mar 2012 08:18
117 lines
4959 bytes
This is a multi-part message in MIME format.

------=_NextPart_000_0060_01CD025A.4C20C2A0
Content-Type: text/plain;
	charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable

FA: UTC HA-107 AUDIO INTERSTAGE TRANSFORMER (Fully-Tested)


http://www.ebay.com/itm/230761522533?ssPageName=3DSTRK:MESELX:IT&_trksid=3D=
p3984.m1555.l2649#ht_500wt_965


Replacing Lundahl interstage transformer with UTC HA-107 was a big =
improvement. Permalloy=20

cores are inherently more linear than silicon steel. They may be not the =
best choice for=20

output transformer due to saturation issue, but for interstage use they =
are unbeatable.
HA-107:

15+15 K primaries=20
45+45 K secondaries=20
20-20,000 Hz 3 dB=20
Pmax 200 mW=20
No unbalanced DC=20
Weight about 4 lb

The core in these transformers is supermalloy (or hypermalloy, as UTC =
called it). It is 80%=20

Ni alloy annealed in hydrogen atmosphere to achieve the highest mu =
(about 20,000 compared to=20

10,000 of 45% Ni permalloy and 5,000 of silicon steel). High =
permeability allows achieving=20

the same inductance with fewer turns, thus decreasing stray inductance =
and winding=20

capacitance. HA-107 has two layers of shielding, external mu metal and =
internal copper.=20

Separate windings allow independent biasing of output tubes.=20

-


------=_NextPart_000_0060_01CD025A.4C20C2A0
Content-Type: text/html;
	charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD>
<META content=3D"text/html; charset=3Diso-8859-1" =
http-equiv=3DContent-Type>
<META name=3DGENERATOR content=3D"MSHTML 8.00.6001.18702">
<STYLE></STYLE>
</HEAD>
<BODY bgColor=3D#ffffff>
<DIV><FONT size=3D2 face=3DArial>FA: UTC HA-107 AUDIO INTERSTAGE =
TRANSFORMER=20
(Fully-Tested)</FONT></DIV>
<DIV>&nbsp;</DIV><FONT size=3D2 face=3DArial>
<DIV><BR><A=20
href=3D"http://www.ebay.com/itm/230761522533?ssPageName=3DSTRK:MESELX:IT&=
amp;_trksid=3Dp3984.m1555.l2649#ht_500wt_965">http://www.ebay.com/itm/230=
761522533?ssPageName=3DSTRK:MESELX:IT&amp;_trksid=3Dp3984.m1555.l2649#ht_=
500wt_965</A></DIV>
<DIV>&nbsp;</DIV>
<DIV><BR>Replacing Lundahl interstage transformer with UTC HA-107 was a =
big=20
improvement. Permalloy </DIV>
<DIV>&nbsp;</DIV>
<DIV>cores are inherently more linear than silicon steel. They may be =
not the=20
best choice for </DIV>
<DIV>&nbsp;</DIV>
<DIV>output transformer due to saturation issue, but for interstage use =
they are=20
unbeatable.<BR>HA-107:</DIV>
<DIV>&nbsp;</DIV>
<DIV>15+15 K primaries <BR>45+45 K secondaries <BR>20-20,000 Hz 3 dB =
<BR>Pmax=20
200 mW <BR>No unbalanced DC <BR>Weight about 4 lb</DIV>
<DIV>&nbsp;</DIV>
<DIV>The core in these transformers is supermalloy (or hypermalloy, as =
UTC=20
called it). It is 80% </DIV>
<DIV>&nbsp;</DIV>
<DIV>Ni alloy annealed in hydrogen atmosphere to achieve the highest mu =
(about=20
20,000 compared to </DIV>
<DIV>&nbsp;</DIV>
<DIV>10,000 of 45% Ni permalloy and 5,000 of silicon steel). High =
permeability=20
allows achieving </DIV>
<DIV>&nbsp;</DIV>
<DIV>the same inductance with fewer turns, thus decreasing stray =
inductance and=20
winding </DIV>
<DIV>&nbsp;</DIV>
<DIV>capacitance. HA-107 has two layers of shielding, external mu metal =
and=20
internal copper. </DIV>
<DIV>&nbsp;</DIV>
<DIV>Separate windings allow independent biasing of output tubes. </DIV>
<DIV>&nbsp;</DIV>
<DIV>-</DIV>
<DIV>&nbsp;</DIV>
<DIV></FONT>&nbsp;</DIV></BODY></HTML>

------=_NextPart_000_0060_01CD025A.4C20C2A0--
Technical Details
Message-ID: <tBh8r.122116$SC3.55621@en-nntp-05.dc1.easynews.com>
Path: arc1-ca.pugleaf.net!h9ni28203pbe.0!nntp.google.com!news1.google.com!npeer01.iad.highwinds-media.com!news.highwinds-media.com!feed-me.highwinds-media.com!news-in-01.newsfeed.easynews.com!easynews!core-easynews-01!easynews.com!en-nntp-05.dc1.easynews.com.POSTED!not-for-mail

Show Full Headers
Complete Article Headers
X-Google-Thread: f7a3a,9a972efe25be3fc0,start
X-Google-NewGroupId: yes
X-Google-Attributes: gida141500be4,domainid0,public,usenet
X-Google-Language: ENGLISH,ASCII-7-bit
Received: by 10.68.201.129 with SMTP id ka1mr1280360pbc.6.1331799513895;
        Thu, 15 Mar 2012 01:18:33 -0700 (PDT)
Path: arc1-ca.pugleaf.net!h9ni28203pbe.0!nntp.google.com!news1.google.com!npeer01.iad.highwinds-media.com!news.highwinds-media.com!feed-me.highwinds-media.com!news-in-01.newsfeed.easynews.com!easynews!core-easynews-01!easynews.com!en-nntp-05.dc1.easynews.com.POSTED!not-for-mail
From: "Mark & Mary Ann Weiss" <mweissXSPAM@mwcomms.com>
Newsgroups: ct.forsale
Subject: FA: UTC HA-107 AUDIO INTERSTAGE TRANSFORMER (Fully-Tested)
Lines: 118
MIME-Version: 1.0
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2900.2180
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2180
Message-ID: <tBh8r.122116$SC3.55621@en-nntp-05.dc1.easynews.com>
X-Complaints-To: abuse@easynews.com
Organization: EasyNews, UseNet made Easy!
X-Complaints-Info: Please be sure to forward a copy of ALL headers otherwise we will be unable to process your complaint properly.
Date: Thu, 15 Mar 2012 03:18:31 -0500
X-Received-Bytes: 4537
Content-Type: multipart/alternative;
 boundary="----=_NextPart_000_0060_01CD025A.4C20C2A0"