Article View: ct.forsale
Article #92FA: UTC HA-107 AUDIO INTERSTAGE TRANSFORMER (Fully-Tested)
From: Mark & Mary Ann Weiss
Date: Thu, 15 Mar 2012 08:18
Date: Thu, 15 Mar 2012 08:18
117 lines
4959 bytes
4959 bytes
This is a multi-part message in MIME format. ------=_NextPart_000_0060_01CD025A.4C20C2A0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable FA: UTC HA-107 AUDIO INTERSTAGE TRANSFORMER (Fully-Tested) http://www.ebay.com/itm/230761522533?ssPageName=3DSTRK:MESELX:IT&_trksid=3D= p3984.m1555.l2649#ht_500wt_965 Replacing Lundahl interstage transformer with UTC HA-107 was a big = improvement. Permalloy=20 cores are inherently more linear than silicon steel. They may be not the = best choice for=20 output transformer due to saturation issue, but for interstage use they = are unbeatable. HA-107: 15+15 K primaries=20 45+45 K secondaries=20 20-20,000 Hz 3 dB=20 Pmax 200 mW=20 No unbalanced DC=20 Weight about 4 lb The core in these transformers is supermalloy (or hypermalloy, as UTC = called it). It is 80%=20 Ni alloy annealed in hydrogen atmosphere to achieve the highest mu = (about 20,000 compared to=20 10,000 of 45% Ni permalloy and 5,000 of silicon steel). High = permeability allows achieving=20 the same inductance with fewer turns, thus decreasing stray inductance = and winding=20 capacitance. HA-107 has two layers of shielding, external mu metal and = internal copper.=20 Separate windings allow independent biasing of output tubes.=20 - ------=_NextPart_000_0060_01CD025A.4C20C2A0 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN"> <HTML><HEAD> <META content=3D"text/html; charset=3Diso-8859-1" = http-equiv=3DContent-Type> <META name=3DGENERATOR content=3D"MSHTML 8.00.6001.18702"> <STYLE></STYLE> </HEAD> <BODY bgColor=3D#ffffff> <DIV><FONT size=3D2 face=3DArial>FA: UTC HA-107 AUDIO INTERSTAGE = TRANSFORMER=20 (Fully-Tested)</FONT></DIV> <DIV> </DIV><FONT size=3D2 face=3DArial> <DIV><BR><A=20 href=3D"http://www.ebay.com/itm/230761522533?ssPageName=3DSTRK:MESELX:IT&= amp;_trksid=3Dp3984.m1555.l2649#ht_500wt_965">http://www.ebay.com/itm/230= 761522533?ssPageName=3DSTRK:MESELX:IT&_trksid=3Dp3984.m1555.l2649#ht_= 500wt_965</A></DIV> <DIV> </DIV> <DIV><BR>Replacing Lundahl interstage transformer with UTC HA-107 was a = big=20 improvement. Permalloy </DIV> <DIV> </DIV> <DIV>cores are inherently more linear than silicon steel. They may be = not the=20 best choice for </DIV> <DIV> </DIV> <DIV>output transformer due to saturation issue, but for interstage use = they are=20 unbeatable.<BR>HA-107:</DIV> <DIV> </DIV> <DIV>15+15 K primaries <BR>45+45 K secondaries <BR>20-20,000 Hz 3 dB = <BR>Pmax=20 200 mW <BR>No unbalanced DC <BR>Weight about 4 lb</DIV> <DIV> </DIV> <DIV>The core in these transformers is supermalloy (or hypermalloy, as = UTC=20 called it). It is 80% </DIV> <DIV> </DIV> <DIV>Ni alloy annealed in hydrogen atmosphere to achieve the highest mu = (about=20 20,000 compared to </DIV> <DIV> </DIV> <DIV>10,000 of 45% Ni permalloy and 5,000 of silicon steel). High = permeability=20 allows achieving </DIV> <DIV> </DIV> <DIV>the same inductance with fewer turns, thus decreasing stray = inductance and=20 winding </DIV> <DIV> </DIV> <DIV>capacitance. HA-107 has two layers of shielding, external mu metal = and=20 internal copper. </DIV> <DIV> </DIV> <DIV>Separate windings allow independent biasing of output tubes. </DIV> <DIV> </DIV> <DIV>-</DIV> <DIV> </DIV> <DIV></FONT> </DIV></BODY></HTML> ------=_NextPart_000_0060_01CD025A.4C20C2A0--
Technical Details
Message-ID:
<tBh8r.122116$SC3.55621@en-nntp-05.dc1.easynews.com>Path:
arc1-ca.pugleaf.net!h9ni28203pbe.0!nntp.google.com!news1.google.com!npeer01.iad.highwinds-media.com!news.highwinds-media.com!feed-me.highwinds-media.com!news-in-01.newsfeed.easynews.com!easynews!core-easynews-01!easynews.com!en-nntp-05.dc1.easynews.com.POSTED!not-for-mailShow Full Headers
Complete Article Headers
X-Google-Thread: f7a3a,9a972efe25be3fc0,start
X-Google-NewGroupId: yes
X-Google-Attributes: gida141500be4,domainid0,public,usenet
X-Google-Language: ENGLISH,ASCII-7-bit
Received: by 10.68.201.129 with SMTP id ka1mr1280360pbc.6.1331799513895;
Thu, 15 Mar 2012 01:18:33 -0700 (PDT)
Path: arc1-ca.pugleaf.net!h9ni28203pbe.0!nntp.google.com!news1.google.com!npeer01.iad.highwinds-media.com!news.highwinds-media.com!feed-me.highwinds-media.com!news-in-01.newsfeed.easynews.com!easynews!core-easynews-01!easynews.com!en-nntp-05.dc1.easynews.com.POSTED!not-for-mail
From: "Mark & Mary Ann Weiss" <mweissXSPAM@mwcomms.com>
Newsgroups: ct.forsale
Subject: FA: UTC HA-107 AUDIO INTERSTAGE TRANSFORMER (Fully-Tested)
Lines: 118
MIME-Version: 1.0
X-Priority: 3
X-MSMail-Priority: Normal
X-Newsreader: Microsoft Outlook Express 6.00.2900.2180
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2180
Message-ID: <tBh8r.122116$SC3.55621@en-nntp-05.dc1.easynews.com>
X-Complaints-To: abuse@easynews.com
Organization: EasyNews, UseNet made Easy!
X-Complaints-Info: Please be sure to forward a copy of ALL headers otherwise we will be unable to process your complaint properly.
Date: Thu, 15 Mar 2012 03:18:31 -0500
X-Received-Bytes: 4537
Content-Type: multipart/alternative;
boundary="----=_NextPart_000_0060_01CD025A.4C20C2A0"