Article View: demon.ip.support.atari
Article #260Re: My Clock has Stopped!
From: David Bolt
Date: Fri, 26 Dec 1997 00:00
Date: Fri, 26 Dec 1997 00:00
46 lines
2605 bytes
2605 bytes
On 24 Dec 1997 11:46:05, Jim Moyes wrote:
> On Tue, 23 Dec 1997 18:18:18 GMT, dbolt@my-ste.demon.co.uk (David Bolt) wrote:
>
> >On 22 Dec 1997 11:35:31, Jim Moyes wrote:
> >> Hi All
> >>
> >> The clock in my Atari ST has stopped.
> >> I assume, like my Pc that it is run off a battery but what size/number etc is
> >> it before I open the case? >> Any info about replacing the battery would be welcome :-)
> >
> >AFAIK the STs don't have a battery backed clock on board although the Mega
> >ST/STEs do. What are the symptoms of it's failure?
> >
> >Regards,
> > David E-Mail :- dbolt@my-ste.demon.co.uk
> I had not used my Atari for a couple of years, had to move to Pc for outside
> reasons but now when I start it up the clock is never set as it was when
> switched off. Does the clock normally need to be reset at start-up, it is such
> a long time since I used it I can't remember? :>)
If it isn't a Mega ST/STE, yes it needs setting at power-up. If you don't
use a clock program during the boot-up, you'll probably need to set it after
every reset.
If you want a clock that keeps the time through resets, I've a couple of
them on my web-site. There are 2 versions, one for an ST with a HD floppy,
and one for the normal DD floppy. The HD floppy version sets the step rate
to 6ms, so the HD floppies are read correctly.
The files are at <URL:http://www.my-ste.demon.co.uk/files/clock.zip> for
the DD version and <URL:http://www.my-ste.demon.co.uk/files/hdclock.zip>
for the HD version. I'll apologize now for the docs, I'm no good at writing
them.
BTW, it doesn't matter if you use the HD version on a normal ST/STE since
the only change was the step rate goes from 3ms to 6ms.
Regards,
David E-Mail :- dbolt@my-ste.demon.co.uk
/**********************************************************\
* *
* Proud owner of: Atari 520STE 4Mb + Syquest EZ-135 + V.34 *
* *
\**********************************************************/
Technical Details
Message-ID:
<883121637.7587.0.nnrp-04.9e98f145@news.demon.co.uk>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<34a0f46b.1775030@news.demon.co.uk>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 112f4b,d6027e0d9942cf88 X-Google-Attributes: gid112f4b,public From: dbolt@my-ste.demon.co.uk (David Bolt) Subject: Re: My Clock has Stopped! Date: 1997/12/26 Message-ID: <883121637.7587.0.nnrp-04.9e98f145@news.demon.co.uk> X-Deja-AN: 310248384 References: <34a0f46b.1775030@news.demon.co.uk> X-NNTP-Posting-Host: my-ste.demon.co.uk [158.152.241.69] Organization: home Newsgroups: demon.ip.support.atari