Article View: demon.tech.pc
Article #34407Re: Ethernet Cable Length
From: Mark Booth
Date: Thu, 15 Apr 1999 00:00
Date: Thu, 15 Apr 1999 00:00
64 lines
3533 bytes
3533 bytes
In article <7ww24BAvpgD3MA5U@electrue.co.uk>, Richard Evans <Richard@electrue.co.uk> writes >Does anyone know what the limit is for max length of CAT 5 cable between >a workstation and a hub. 100m, including trunk wiring, and patch wiring at either end if appropriate. >I have to extend our network over a distance of >about 600 metres too multiple workstations. I have just installed a couple of Edimax TF3202TF 2*port 10/100Mbps Fast Ethernet switches. They have a 10/100BaseTX port and a 100BaseFX port (ST connectors). They support Full wire speed cut through, fragment free cut through and store and forward switching. In full duplex mode, they support Fibres up to 2km. They cost 140quid +VAT each, and 4 fibre pre-terminated (ST) fibre bundles can be bought for about 25 quid plus 1.6quid/m. Halve this price if you want to dispense with the redundancy of 2 spare fibres, and you will probably get discount on this sort of price if you are going for a 600m run. Going for fibre has the distinct advantage that when you upgrade the rest of your network to 100Mbps, you wont be stuck with only a 10Mbps link between your distant offices. >I am presuming that this >would need some form of booster. Also I believe that there is limit to >the number of hubs that can be joined on an ethernet network and that >this is fairly low, something like 5 24 port hubs, is this correct or >am I talking rubbish. Personally, if you have 5 24port hubs, I would recommend connecting them by a 5 or 8 port switching hub, segmenting your network into 5 collision domains, and vastly increasing network bandwidth. You can also put servers on your hub switch. Use 10/100 switches and your servers will go from having 10/20Mbps bandwidth to having 100/200Mbps. My network has a top level 5 port 100baseTX switching hub. One of these ports is connected to the Fibre, another couple to servers, and another two to other hubs. The other end of the fibre is connected to another hub. The hubs connect to a mixture of 100baseTX and 10baseT workstations. All of this only cost about 750quid plus VAT (excluding fibre). It gives us an almost completely switched system (i.e. all workstations have 20Mbps or 200Mbps full duplex bandwidth each) rather than our old 10base2 system, which had 10Mbps shared between all workstations and servers. So far I am very impressed with the system. Now if only I could get the print servers to stop unnecessarily broadcasting to the network... Take care, Mark......... -- Mark Booth - My ReplyTo: address is valid, other addresses are for tracking UCE -------------------------- markbSig@oxim.demon.co.uk -------------------------- OxIM Ltd. Registered Office 12 Kings Meadow, Ferry Hinksey Road, Oxford OX2 0DP Voice +44(0)1865 204881, Fax +44(0)1865 204882 Registered in England 3619439
Technical Details
Message-ID:
<OfalgDA9TgF30A8i@oxim.demon.co.uk>Path:
arc1-ca.pugleaf.net!unknown!not-for-mailReferences:
<7ww24BAvpgD3MA5U@electrue.co.uk>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 1036bc,5bf495d5beca8be8 X-Google-Attributes: gid1036bc,public From: Mark Booth <markbFrom2@oxim.demon.co.uk> Subject: Re: Ethernet Cable Length Date: 1999/04/15 Message-ID: <OfalgDA9TgF30A8i@oxim.demon.co.uk> X-Deja-AN: 466748099 X-NNTP-Posting-Host: oxim.demon.co.uk:158.152.26.40 References: <7ww24BAvpgD3MA5U@electrue.co.uk> X-Complaints-To: abuse@demon.net X-Trace: news.demon.co.uk 924190060 nnrp-13:24069 NO-IDENT oxim.demon.co.uk:158.152.26.40 Organization: OxIM Ltd. MIME-Version: 1.0 Reply-To: Mark Booth <markbReplyTo@oxim.demon.co.uk> Newsgroups: demon.tech.pc