Re: Ethernet Cable Length

#34552
From: Ernest
Date: Mon, 12 Apr 1999 00:00
21 lines
1527 bytes
In article <19990410.1518.4666snz@michaels.demon.co.uk>
           4ms2u$ms@michaels.demon.co.uk "Michael Salem" writes:

> I don't see that you can connect 30 hubs: wouldn't they fall foul of 
> the IEEE standard:
>    The transmission path permitted between any two DTEs may consist
>    of up to five segments, four repeater sets (including optional
>    AUIs), two MAUs, and two AUIs. 

Hi Michael

If all hubs are connected to a thin ethernet backbone, then the
transmission path between any 2 dte's will only contain 3 segments.
3com officeconnect hub instructions says you can connect 30 hubs on
the single segment thin e'net backbone. DLink mini hub instructions
say exactly the same. So, I guess it's ok? I've not tried. :)

Ernest
-- 
ernest     at Noel Systems, near Kingston-upon-Thames (UK)
           (if replying by email, use postmaster)
Technical Details
Message-ID: <923914153snz@noelsys.demon.co.uk>
Path: arc1-ca.pugleaf.net!unknown!not-for-mail
References: <7ww24BAvpgD3MA5U@electrue.co.uk> <19990410.1518.4666snz@michaels.demon.co.uk>

Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit
X-Google-Thread: 1036bc,5bf495d5beca8be8
X-Google-Attributes: gid1036bc,public
From: ernest@noelsys.demon.co.uk (Ernest)
Subject: Re: Ethernet Cable Length
Date: 1999/04/12
Message-ID: <923914153snz@noelsys.demon.co.uk>
X-Deja-AN: 465558447
References: <7ww24BAvpgD3MA5U@electrue.co.uk> <19990410.1518.4666snz@michaels.demon.co.uk>
X-Complaints-To: abuse@demon.net
X-Mail2News-Path: news.demon.net!noelsys.demon.co.uk
X-Trace: mail2news.demon.co.uk 923940795 mail2news:7813 mail2news mail2news.demon.co.uk
Organization: Noel Systems
Reply-To: ernest@noelsys.demon.co.uk
Newsgroups: demon.tech.pc