On 2 Sep 91 13:51:20 GMT, cpcahil@virtech.uucp (Conor P. Cahill) said: cpcahil> pcg@aber.ac.uk (Piercarlo Antonio Grandi) writes: pcg> Same goes for EISA SCSI disk controllers (the most expensive SCSI pcg> disks top out at 4MB/s, and most cannot do more more than 1.5MB/s pcg> off the platter). In practice EISA is only needed for very high pcg> speed graphics (good luck with that) and for disk arrays, or, pcg> theoretically, for very high bandwidth tapes. cpcahil> Throughput is not the only evaluation factor for a disk cpcahil> controller. Another factor, which is where a good EISA cpcahil> controller will shine, is the amount of time the bus is tied up cpcahil> transferring that 4MB/s. Latency then perhaps matters. But in practice not a lot... cpcahil> You yourself said that the theoretical max for the ISA bus was cpcahil> between 5 and 6 MB/s. 4MB/s is appox 80% of the theoretical cpcahil> max. Of course, but this is nearly irrelevant. Almost nobody keeps their SCSI bus running at its top rated bandwidth continuously (not even Adaptec, which stay off the bus for some programmable fraction of the time). In particular disk access tends, in normal operation, to be bursty (the effect of caching and paging, and then of intervening seeks). Also, most disks currently available don't do much more than 1.3MB sustained, so having two such disks gives you, if both are active together, an instantaneous bandwidth of 2.6MB/s, but on average they will not be both active together, and theat will not in acase last long. In practice 5-6MB/s is many times than the *average* bandwidth required, and it is twice the highest instantaneous load you can expect to see in a small to medium general purpose timesharing system. cpcahil> With a good EISA controller that same 4MB/s can take up only cpcahil> 12% of the theoretical max, thereby freeing the bus up for cpcahil> other operations. The problem is that, except for very large systems running very large loads, or particular cases, there are no other operations. All CPU memory access, the real pig, is via a private bus, and only tapes, disks, communications and framebuffers use the ISA bus, and their combined *average* utilization is nowhere its saturation point, and their *peak* is also accomodated more or less easily. pcg> First of all, the good news: as I have said almost any modern pcg> Ethernet card will deliver substantially all of the Ethernet pcg> bandwidth, and this bandwidth is at worst one fifth of the ISA bus pcg> bandwidth, so you don't need any EISA cpcahil> Giving up 20% of the bus bandwidth just to handle ethernet i/o cpcahil> sounds like a good reason to go with EISA. 20% is alot of the cpcahil> system. Yes, but you are not transferring 1MB/s constantly thru your Ethernet adapter, I hope. And if you are, then most people have pretty low average Ethernet adapter utilizations. Quite surprisingly :-) the highest bandwidth user is likely to be the frame buffer: SVGA cards, which are pretty slow as frame buffers go, can require 2MB/s, and, if you are doing image processing, sustainedly. But a 2MB/s video card will almost surely need a 2MB/s disk/tape subsystem, and this is not the sort of application that I would do with ISA, I would definitely do it with EISA. I would also use EISA for largish (more than (perhaps half) a dozen users) timesharing. -- Piercarlo Grandi | ARPA: pcg%uk.ac.aber@nsfnet-relay.ac.uk Dept of CS, UCW Aberystwyth | UUCP: ...!mcsun!ukc!aber-cs!pcg Penglais, Aberystwyth SY23 3BZ, UK | INET: pcg@aber.ac.uk
Technical Details
Message-ID:
<PCG.91Sep9185229@aberdb.aber.ac.uk>Path:
arc1-ca.pugleaf.net!gmdzi!unido!mcsun!ukc!dcl-cs!gdt!aber!aberda!pcgReferences:
<1991Aug27.192220.20958@world.std.com> <1991Sep1.195029.16374@aber.ac.uk> <1991Sep02.135120.17736@virtech.uucp>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 10a29b,adc43bc691337774 X-Google-Attributes: gid10a29b,public X-Google-Thread: 1048e3,adc43bc691337774 X-Google-Attributes: gid1048e3,public X-Google-Thread: 1122ea,adc43bc691337774 X-Google-Attributes: gid1122ea,public X-Google-Thread: f9325,adc43bc691337774 X-Google-Attributes: gidf9325,public X-Google-Thread: 10f9b1,adc43bc691337774 X-Google-Attributes: gid10f9b1,public X-Google-Thread: 12ca36,bf24dff74f21bc6 X-Google-Attributes: gid12ca36,public X-Google-ArrivalTime: 1991-09-09 15:18:54 PST Path: arc1-ca.pugleaf.net!gmdzi!unido!mcsun!ukc!dcl-cs!gdt!aber!aberda!pcg From: pcg@aber.ac.uk (Piercarlo Grandi) Newsgroups: list.sco,comp.protocols.tcp-ip,comp.protocols.tcp-ip.ibmpc,biz.sco.general,comp.unix.sysv386,comp.unix.wizards Subject: Re: Need help selecting Ethernet cards for very high throughput rates. Message-ID: <PCG.91Sep9185229@aberdb.aber.ac.uk> Date: 9 Sep 91 18:52:29 GMT References: <1991Aug27.192220.20958@world.std.com> <1991Sep1.195029.16374@aber.ac.uk> <1991Sep02.135120.17736@virtech.uucp> Sender: news@aber.ac.uk (USENET news service) Reply-To: pcg@aber.ac.uk (Piercarlo Grandi) Organization: Coleg Prifysgol Cymru Lines: 74 In-Reply-To: cpcahil@virtech.uucp's message of 2 Sep 91 13: 51:20 GMT Nntp-Posting-Host: aberdb