From: Brian Atkins
Date: Wed, 11 Jun 1986 14:50
14 lines
1374 bytes
I have a question about how to handle an MPDU which is too long.
I can't find anything in the CCITT X.400 recommendations which will
allow the receiving MTAE to choke gracefully on an MPDU which is too large.
None of the session exception or abort stuff handle it (as defined in X.410),
and there are no applicable RTS elements either.  Does this imply that the 
receiving MTAE must accept responsibility for the message and then send a 
non-delivery notice even though the message was not received in full?

Also, what are some other forums for X.400 discussions. I have sent
a subscription request to the MHS lists out of BRL and MIT, but haven't
heard anything.

Brian Atkins   ...{attunix, hao, allegra, ucbvax}!nbires!atkins
NBI Inc., P.O. Box 9001, Boulder CO 80301	(303) 444-5710
Technical Details
Message-ID: <8606111450.AA01332@opus>
Path: arc1-ca.pugleaf.net!utzoo!decvax!bellcore!petrus!scherzo!allegra!princeton!caip!seismo!styx!nbires.UUCP!atkins

Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP
Path: arc1-ca.pugleaf.net!utzoo!decvax!bellcore!petrus!scherzo!allegra!princeton!caip!seismo!styx!nbires.UUCP!atkins
From: atkins@nbires.UUCP (Brian Atkins)
Newsgroups: mod.protocols
Subject: X.400 question
Message-ID: <8606111450.AA01332@opus>
Date: Wed, 11-Jun-86 10:50:46 EDT
Article-I.D.: opus.8606111450.AA01332
Posted: Wed Jun 11 10:50:46 1986
Date-Received: Thu, 12-Jun-86 19:24:01 EDT
Sender: daemon@styx.UUCP
Organization: The ARPA Internet
Lines: 14
Keywords: X.400 MHS CCITT
Approved: protocols@red.rutgers.edu