We have a noise problem with our RS-232 lines at work. We run pins 1,2, and 3
(with 7 shorted to 1)
for 2 lines in every office. Unfortunately, the 6 wires are run on a single
cable; the 2 lines are not shielded from each other. This still works OK
if someone has 2 terminals in their office or on terminals with multiple
ports. However, folks who use a T-switch to switch between their 2 lines
in their office will reliably send garbage down the unselected line.
Has anyone solved a similar problem? I'm guessing the what will
is to put a load between pins 1 and 3 on the unselected line. To do this
automatically, we'd use a matrix switch instead of the t-switch:
Computer A ====== Terminal * Computer A == == Terminal
O \/
R /\
Computer B ====== Resistor * Computer B == == Resistor
Will this work? Am I in any danger of damaging our computer terminal
boards? Any estimate of an appropriate value for the resistor?
-------
Technical Details
Message-ID:
<8603060705.AA05792@ucbvax.berkeley.edu>Path:
arc1-ca.pugleaf.net!utzoo!decvax!bellcore!ulysses!ucbvax!telecomShow Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site ucbvax.BERKELEY.EDU Path: arc1-ca.pugleaf.net!utzoo!decvax!bellcore!ulysses!ucbvax!telecom From: S.PAE@DEEP-THOUGHT.MIT.EDU (Philip A. Earnhardt) Newsgroups: mod.telecom Subject: RS-232 problem Message-ID: <8603060705.AA05792@ucbvax.berkeley.edu> Date: Tue, 4-Mar-86 14:16:02 EST Article-I.D.: ucbvax.8603060705.AA05792 Posted: Tue Mar 4 14:16:02 1986 Date-Received: Thu, 6-Mar-86 22:19:25 EST Sender: daemon@ucbvax.BERKELEY.EDU Organization: The ARPA Internet Lines: 20 Approved: telecom@xx.lcs.mit.edu