<shep siegel at datacube in 3200006@datacube writes>:
>Thanks for the post of the DSP56200. It is good to be able to read of
>new DSP chip architectures here in net.arch. I assume that the DSP56200
>is designed as a peripheral for the 56000.
>Table 1, listing the DSP56200 "performance figures" did not make any
>sense: It seems for a FIR filter application with, say, 32 taps,
>the maximum sampling frequency DECREASES as you add chips. This doesn't
>make any sense. Can anyone explain or correct?
thanks for catching this serious error in the table. the correction is
below.
TABLE I - DSP56200 Performance Figures
SINGLE CHIP
--------------------------------------------
| Maximum Sampling Frequency (KHz) |
--------------------------------------------
| | Number of Taps |
| Mode | 32 64 128 256 |
--------------------------------------------
| FIR Filter | 227 132 71 37 |
| Adaptive Filter | 123 69 37 19 |
| Dual FIR Filters | 122 68 36 * |
--------------------------------------------
FOUR CHIPS
--------------------------------------------
| Maximum Sampling Frequency (KHz) |
--------------------------------------------
| | Number of Taps |
| Mode | 128 256 512 1024 |
--------------------------------------------
| FIR Filter | 222 132 71 37 |
| Adaptive Filter | 120 69 37 19 |
--------------------------------------------
EIGHT CHIPS
--------------------------------------------
| Maximum Sampling Frequency (KHz) |
--------------------------------------------
| | Number of Taps |
| Mode | 256 512 1024 2048 |
--------------------------------------------
| FIR Filter | 204 132 71 37 |
| Adaptive Filter | 115 69 37 19 |
--------------------------------------------
SIXTEEN CHIPS
--------------------------------------------
| Maximum Sampling Frequency (KHz) |
--------------------------------------------
| | Number of Taps |
| Mode | 512 1024 2048 4096 |
--------------------------------------------
| FIR Filter | 175 132 71 37 |
| Adaptive Filter | 105 69 37 19 |
--------------------------------------------
Technical Details
Message-ID:
<744@oakhill.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!watmath!clyde!caip!im4u!oakhill!dspShow Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!watmath!clyde!caip!im4u!oakhill!dsp From: dsp@oakhill.UUCP (DSP Account) Newsgroups: net.arch,net.analog,net.dcom Subject: Correction to DSP56200 Tech Summary Table I Message-ID: <744@oakhill.UUCP> Date: Fri, 8-Aug-86 13:38:57 EDT Article-I.D.: oakhill.744 Posted: Fri Aug 8 13:38:57 1986 Date-Received: Sat, 9-Aug-86 11:17:31 EDT Organization: Motorola Inc. Austin, Tx Lines: 61 Keywords: sampling frequency and number of taps