From: Dave Clemans <dgc at SDC-NET> It probably should be explicitly stated in the documentation that the RL01/RL02 bootstrap does NOT look at the switch register (and if non-zero, read a pathname from the console), while most of the other bootstraps do. The 2.8 tape that we got did not have an RM02/RM03 first level bootstrap; but by changing the 19 to 5, etc. in the RM05 boot you do get a working RM02/RM03 boot. The xp.c driver works for the new System Industries 6100 controller board (with the proviso that the previously given out fix to not depend on PIP as a ready bit is applied). The BEP chip on the 6100 is working quite nicely; we're running it with a Fujitsu 160MB drive, and we are not seeing any ECC errors, even on the sectors that Fujitsu marked uncorrectable. (Both under UNIX and the System Industries diagnostics). Dave Clemans
Technical Details
Message-ID:
<anews.Aucbvax.6328>Path:
arc1-ca.pugleaf.net!utzoo!decvax!ucbvax!randvax!sdcnet!dgcShow Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!utzoo!decvax!ucbvax!randvax!sdcnet!dgc From: sdcnet!dgc Newsgroups: net.bugs.2bsd Subject: Misc. comments Date: Sun, 28 Feb 1982 17:18:21 +0000 Message-ID: <anews.Aucbvax.6328>