Re: TSX-Plus/RT-11 Help Wanted

#11
From: John Miller
Date: Sun, 06 Oct 1985 21:38
17 lines
1421 bytes
All he needs to do is to modify TSGEN.MAC (between the "======"'s that
mark the user-configurable parameters.  RT-11 multiterminal support is
NOT required.  

If he has any difficulty bringing TSX+ up after the regeneration, he might
need to reduce the size of RT-11 by regenerating the RT-11 baseline or
single job monitor, but that's unlikely.  Also, if the system seems to
crash frequently with a "no free fork blocks" message, he may need to 
increase NUMFRK (near the beginning of TSGEN.MAC).  With the RT-11 baseline
monitor, 14 lines running on two DZ-11 multiplexors, and NUMFRK = 170, 
we have few problems on an 11/24.  
  
-- 

                        John Miller  (ecsvax!phco)
                        Dept. of Pharmacology, Univ. of N.C.-Chapel Hill
                        Chapel Hill, NC 27514       (919) 966-4628
Technical Details
Message-ID: <538@ecsvax.UUCP>
Path: arc1-ca.pugleaf.net!utzoo!linus!decvax!mcnc!ecsvax!phco
References: <12035@rochester.UUCP>

Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP
Posting-Version: version B 2.10.2 9/18/84; site ecsvax.UUCP
Path: arc1-ca.pugleaf.net!utzoo!linus!decvax!mcnc!ecsvax!phco
From: phco@ecsvax.UUCP (John Miller)
Newsgroups: net.decus
Subject: Re: TSX-Plus/RT-11 Help Wanted
Message-ID: <538@ecsvax.UUCP>
Date: Sun, 6-Oct-85 17:38:58 EDT
Article-I.D.: ecsvax.538
Posted: Sun Oct  6 17:38:58 1985
Date-Received: Wed, 9-Oct-85 03:40:14 EDT
References: <12035@rochester.UUCP>
Reply-To: phco@ecsvax.UUCP (John Miller)
Organization: Univ. of North Carolina at Chapel Hill
Lines: 17