Article View: net.decus
Article #29Re: RT-11/TSX-plus and dialins
From: Mike Ciaraldi
Date: Tue, 05 Nov 1985 05:29
Date: Tue, 05 Nov 1985 05:29
55 lines
2927 bytes
2927 bytes
>
> I am trying to set up a dialin line on a PDP-11/23 running TSX-plus
> from across the country. As you can imagine, it's a bit hard to debug.
>
> With the LINDEF set up normally (i.e. without $PHONE or anything special)
> I can log in fine, but when I logout, or the call terminates, or the
> connection is broken in any manner, the entire system crashes right down
> to the @-prompt. When I change the LINDEF to contain a $PHONE switch,
> this doesn't happen, but it logs me out after approximately ten seconds
> of connect time. It strikes me that the second method is the right one,
> if I can figure out how to keep from getting logged out.
>
> Is there something special I need in my LINE5.TSX file? Does anybody
> know how to deal withthis/
> ?
> THanks.
> GLenn Reid
> {decwrl,glacier,sun}!adobe!greid
> --
> You have new mail.
I just redid a TSX system to accept a modem, and it worked OK
(after getting help from a lot of people via net.decus).
I was using a Hayes Smartmodem 1200 connected to a DLV-11J.
I tried using the $PHONE flag and this DOES NOT work for this
configuration. The reason is that the $PHONE flag makes TSX look for
the modem status signals which indicate that it is properly receiving
a carrier from the remote modem. If not, it
logs you out again.
A DLV-11J only has connector pins for data in, data out, and ground,
so there is no way to tell it that the modem has answered the
phone.
The only LSI-11 interface card thgat supports these
signals is, I believe, the DLV-11E, which is a single-line
serial card (the J is a four-line, non-multiplexed).
Anyway, I set the LINDEF up exactly like the other 4
lines, and also changed the macro that defines the
total number of lines.
One problem that cropped up later is that
the other lines had been set for 100-character I/O buffers
on the serial lines. This is too small for KERMIT file transfer
(to the 11 from a PC), so we will bump iit up to 110.
Thre other thing I had to do was tell the Smartmodem not
to send result codes or echo commands, else the
characters sent (e.g. "RING" bounce back and
forth forever).
Good luck. I hope that my recent expereince gives you
hope. I am sure that others on the net will also be glad to help you.
Mike Ciaraldi
seismo!rochester!ciaraldi
Technical Details
Message-ID:
<12884@rochester.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!allegra!mit-eddie!think!harvard!seismo!rochester!ciaraldiReferences:
<771@adobe.UUCP>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.2 9/18/84; site rochester.UUCP Path: arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!allegra!mit-eddie!think!harvard!seismo!rochester!ciaraldi From: ciaraldi@rochester.UUCP (Mike Ciaraldi) Newsgroups: net.decus Subject: Re: RT-11/TSX-plus and dialins Message-ID: <12884@rochester.UUCP> Date: Tue, 5-Nov-85 00:29:25 EST Article-I.D.: rocheste.12884 Posted: Tue Nov 5 00:29:25 1985 Date-Received: Thu, 7-Nov-85 04:37:36 EST References: <771@adobe.UUCP> Organization: U. of Rochester, CS Dept. Lines: 55