Article View: net.graphics
Article #1355Re: Tektronix 4695 Color Printer Problems
From: George Rich
Date: Fri, 01 Aug 1986 18:24
Date: Fri, 01 Aug 1986 18:24
58 lines
3416 bytes
3416 bytes
In article <130@eeg.UUCP>, bcx@eeg.UUCP writes:
> We, at EEG Systems, are interested in hearing what experiences others
> have had with the reliability of the Tektronix 4695 color printers. Has
> anyone had bad experiences, and if so, what kind? We're wondering
> because we were having some problems, and wanted to know if we were the
> only ones (as Tektronix seems to be claiming).
>
> --
> Bryan Costales, EEG Systems Laboratory
> 1855 Folsom St, San Francisco, Ca 94103 (415) 621-8343
> {ihnp4,lll-crg,dual,qantel,pyramid}!ptsfa!eeg!bcx
We have also had trouble with the Tektronix 4965 color copier.
After several visits from our factory service represenitive, one of
them final made a few suggestions that seem to work.
1. When changing the ink cartiages, place a few drops of
distilled water or Tektronix cleaning fluid, Tektronix
part number 016-0732-00, into the ink resavior before
installing the new cartiage. The following amounts
should be put into each resavior:
BLACK ............. 20 DROPS
YELLOW ............ 10 DROPS
MAGENTA ........... 10 DROPS
CYAN .............. 10 DROPS
This will help to prevent the ink from thicking and pluging
the ink jet.
2. Make sure that the "printhead maintenance liquid container"
is changed about once a month. This can be replaced by print-
head maintenance liquid or distilled water.
3. If the color copier is not used reguarly for color print outs,
then running the self test daily or ever other day will help
prevent the ink jets from drying out. Only a few lines need to
be printed in order to keep the ink jets clear.
4. The print head surface can be cleanded by following the pro-
cedure in the operators manual, Tektronix part number 070-
4646-00. This procedure is found in section 4, page 3.
5. The ink jets can be cleaned by following the the procedure in
operators manual, section 4, page 10. This method should be
tried first and that fails then try setcion 4, page 17.
Hopefully the above procedures will work to correct some of the
problems that you are have with the color copier.
George B. Rich
Frequency Domain Instrumentation
Tektronix, Inc.
rich@tekfdi.TEK.COM
Disclaimer: These views do not necessarily represent the
views of Tektronix, Inc.
Technical Details
Message-ID:
<443@tekfdi.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!seismo!ut-sally!husc6!harvard!panda!genrad!decvax!tektronix!tekcrl!vice!tekfdi!richReferences:
<130@eeg.UUCP>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!mnetor!seismo!ut-sally!husc6!harvard!panda!genrad!decvax!tektronix!tekcrl!vice!tekfdi!rich From: rich@tekfdi.UUCP (George Rich) Newsgroups: net.graphics,net.unix Subject: Re: Tektronix 4695 Color Printer Problems Message-ID: <443@tekfdi.UUCP> Date: Fri, 1-Aug-86 14:24:02 EDT Article-I.D.: tekfdi.443 Posted: Fri Aug 1 14:24:02 1986 Date-Received: Sat, 2-Aug-86 23:04:23 EDT References: <130@eeg.UUCP> Organization: Tektronix, Inc., Beaverton, OR Lines: 58 Summary: 4695 Possible solutions