Article View: net.lan
Article #1081Re: How do I cable an Ethernet?
From: Phil Ngai
Date: Wed, 07 May 1986 19:59
Date: Wed, 07 May 1986 19:59
28 lines
1860 bytes
1860 bytes
In article <546@rdin.UUCP> perl@rdin.UUCP (Robert Perlberg) writes:
>Is there any truth to the rumor I heard that plain RS-232 type cable
>can be used to connect Ethernet transceivers?
You could probably use telephone cable if it was short enough. (six
inches?) "plain RS-232 type cable" is pretty ambigious. I have been
tempted to use Belden 9891 Ethernet transceiver cable for RS-232.
Clearly I could convert that "RS-232" cable for transceiver cable use.
I have seen people use short lengths of flat ribbon cable for
transceiver cables (Interlan).
If you are going 50 meters then things get a little tougher.
The main considerations are that you need to supply 500 mA over 50
meters with only 2 volts of loss for the power and that the signals
are differential so you ought to use twisted pair for the
transmit/receive/collision signals. There are also crosstalk
requirements which are usually met by shielding each pair and then
shielding the entire cable as well.
IEEE 802.3 adds a fifth pair but I don't know if anyone uses it yet.
Anyone seen it?
--
If a reactor melts down in Russia will they call it the America syndrome?
Phil Ngai +1 408 749 5720
UUCP: {ucbvax,decwrl,ihnp4,allegra}!amdcad!phil
ARPA: amdcad!phil@decwrl.dec.com
Technical Details
Message-ID:
<11599@amdcad.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!allegra!amdcad!philReferences:
<546@rdin.UUCP>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Posting-Version: version B 2.10.3 4.3bsd-beta 6/6/85; site amdcad.UUCP Path: arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!allegra!amdcad!phil From: phil@amdcad.UUCP (Phil Ngai) Newsgroups: net.lan Subject: Re: How do I cable an Ethernet? Message-ID: <11599@amdcad.UUCP> Date: Wed, 7-May-86 15:59:50 EDT Article-I.D.: amdcad.11599 Posted: Wed May 7 15:59:50 1986 Date-Received: Thu, 8-May-86 22:04:38 EDT References: <546@rdin.UUCP> Reply-To: phil@amdcad.UUCP (Phil Ngai) Organization: AMD, Sunnyvale, California Lines: 28