Article View: net.micro.att
Article #1011AT-HDU-POD error help
From: slif
Date: Fri, 23 May 1986 20:16
Date: Fri, 23 May 1986 20:16
51 lines
2786 bytes
2786 bytes
[]
I have written some of the diagnostic software in use here
at Olivetti for their M28, which is an AT-compatible computer,
certainly one of the best to be unleashed to the world.
[No kidding! I've seen other manufacturer's feeble attempts].
I wanted to check the power-on diagnostic software to see
if it would detect unusual conditions and report them.
I removed various cables, and recorded the message which appeared.
I used an Olivetti M28 prototype computer with a Western Digital
WD1002-WAH disk controller and OPE 5221 disk drive.
[This may or may not be a configuration one can purchase].
Out of this effort I made some observations which I think are
useful to people using AT-like computers. The results of my
observations are presented below in a quick lookup fashion.
THIS IS NOT INTENDED AS A FIELD SERVICE GUIDE.
NEITHER OLIVETTI NOR MIKE SLIFCAK ARE LIABLE FOR USING THIS INFORMATION.
In general, turn the power OFF first. I like to unplug
the computer from the wall in case there are exposed AC wires
inside the box [found rarely these days-but I'm cautious |-)].
Also, make sure that pin 1 at the controller is connected to
pin 1 at the drive [Ignore color stripes- match numbers or square
solder pads on the printed circuit boards' interfaces].
MESSAGE UPON THE CONSOLE CONSTRUCTIVE MOTION
1780 Disk 0 failure
1781 Disk 1 failure re-seat the power cable to the drive.
check the power cable at the supply end.
replace frayed or broken power cable.
re-seat the control cable.
replace control cable if message continues.
1782 Disk controller failure re-seat controller in slot.
replace controller if message continues.
1790 Disk 0 error
1791 Disk 1 error re-seat the data cable.
replace data cable if message continues.
--------------------------------------------------------------------------
Please post responses to me at:
UUCP: {hplabs,ihnp4,allegra}!oliveb!oliven!slif
As usual, I thank Olivetti for access to the net,
and I do not represent them in this posting.
Technical Details
Message-ID:
<874@oliveb.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!bellcore!decvax!decwrl!pyramid!pesnta!epimass!oliveb!slifShow Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!bellcore!decvax!decwrl!pyramid!pesnta!epimass!oliveb!slif From: slif@oliveb.UUCP Newsgroups: net.micro.att,net.micro.pc Subject: AT-HDU-POD error help Message-ID: <874@oliveb.UUCP> Date: Fri, 23-May-86 16:16:41 EDT Article-I.D.: oliveb.874 Posted: Fri May 23 16:16:41 1986 Date-Received: Sun, 25-May-86 18:24:39 EDT Distribution: net Organization: Olivetti ATC; Cupertino, Ca Lines: 51