I'm not certain, but this problem might be caused by the PLUS insisting on having Carrier Detect always high. If the Penril can be configured that way (dip switch or software), then do it. Otherwise make an EIA connector that will pin CD to DTR and keep it high. Harvey S. Cohen, AT&T Lincroft, NJ, mtuxo!hsc
Technical Details
Message-ID:
<2007@mtuxo.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!mnetor!seismo!lll-crg!lll-lcc!qantel!ihnp4!houxm!mtuxo!hscReferences:
<558@iham1.UUCP>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!mnetor!seismo!lll-crg!lll-lcc!qantel!ihnp4!houxm!mtuxo!hsc From: hsc@mtuxo.UUCP (h.cohen) Newsgroups: net.micro.att Subject: Re: Help 6300+ and Penril ACU Message-ID: <2007@mtuxo.UUCP> Date: Thu, 25-Sep-86 17:10:41 EDT Article-I.D.: mtuxo.2007 Posted: Thu Sep 25 17:10:41 1986 Date-Received: Fri, 26-Sep-86 18:45:34 EDT References: <558@iham1.UUCP> Organization: AT&T Information Systems Labs, Holmdel NJ Lines: 6 Keywords: 6300+, Penril ACU