In article <322@ttidca.UUCP> josephs@ttidca.UUCP writes:
>
>	Does anyone have any experience, thoughts or ideas about the ARC
>disk controller card is advertised in on page 173 of the June 17th 
>issue of PC-Week?  The blurb says that it supports a 1-1 interleave 
>factor vs. 1-6 for the standard XT disk.  Does it use onboard 
>memory to "buffer" a full track of disk data?  Does one need to
>reformat a disk if the ARC card is used to replace another controller?
>What about fragmented disks files -- doesn't this defeat the speed
>advantage?
------
Besides my 6300 I have a Televideo TeleCAT-286.  It's controller does
double buffering and reads a track at a time, so the interleave factor
is 1.  Although the drive is a Microscience 3425 (20M, 85ms avg. access),
disk access is EXTRAORDINARILY fast, even compared to a 40 ms AT drive.
If my drive were totally fragmented, that is, each file were split up into
individual sectors on different places around the disk, then my drive would
simply be the same speed as another with a different interleave factor in the
same condition.  This is virtually never the case, and several disk utilities
on the market can unfragment drives.
I unfortunately don't know the ARC controller, but I highly doubt TV makes
their own.  Perhaps it's the same one.  There must be more than one that
works this way by now.
You change the interleave factor WHEN and only when you do a low level disk
format.  You need to write info saying where the next logical sector is.


*

        *************************************************
        *       Jeff Miller                             *
        *       Multimate International Corp.           *
        *       52 Oakland Avenue                       *
        *       East Hartford, CT  06108-9911           *
        *       (203) 522-2116 x257                     *
        *  UUCP:                                        *
        * ...!seismo!utah-cs!utah-gr!pwa-b!mmintl!jeffm *
        *                                               *
 -->    * P.S. I can't *mail* to ARPA but I can receive *    <--
 -->    * from there.  News I *post* should get there.  *    <--
        *************************************************
*
Technical Details
Message-ID: <1604@mmintl.UUCP>
Path: arc1-ca.pugleaf.net!utzoo!linus!philabs!pwa-b!mmintl!jeffm
References: <322@ttidca.UUCP>

Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP
Path: arc1-ca.pugleaf.net!utzoo!linus!philabs!pwa-b!mmintl!jeffm
From: jeffm@mmintl.UUCP (Jeffrey Miller)
Newsgroups: net.micro.pc,net.micro.att
Subject: Re: ARC Disk Controller Card (1:1 interleave factor)
Message-ID: <1604@mmintl.UUCP>
Date: Thu, 26-Jun-86 14:41:17 EDT
Article-I.D.: mmintl.1604
Posted: Thu Jun 26 14:41:17 1986
Date-Received: Sun, 29-Jun-86 00:37:19 EDT
References: <322@ttidca.UUCP>
Reply-To: jeffm@mmintl.UUCP (Jeffrey Miller)
Organization: Multimate International, E. Hartford, CT
Lines: 42