In article <240@sphinx.UChicago.UUCP>, cjdb@sphinx.UChicago.UUCP (Charles Blair) writes:
>
> I received the error code 601 when running diagnostics on the B: drive
> of an IBM PC/AT. Does anyone know what exactly the code means? Guide to
> Operations just says to have the system unit serviced.
601 ~means "I don't see it at all." It is reported when there is
no response from the drive. I would reseat the power plug and jumpers
(there should be no terminating resistor in B:). The signal/data card
edge connector is probably OK since A: works (it is after B: on the
cable) but clean the contacts and reseat anyway. You could also check
for continuity across the cable.
--
Gerald Lotto - Harvard Chemistry Dept.
UUCP: {seismo,harpo,ihnp4,linus,allegra,ut-sally}!harvard!lhasa!lotto
ARPA: lotto@harvard.EDU
CSNET: lotto%harvard@csnet-relay
Technical Details
Message-ID:
<598@talcott.UUCP>Path:
arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!allegra!princeton!caip!seismo!harvard!husc6!talcott!lottoReferences:
<240@sphinx.UChicago.UUCP>Show Full Headers
Complete Article Headers
Relay-Version: version B 2.10 5/3/83; site utzoo.UUCP Path: arc1-ca.pugleaf.net!utzoo!watmath!clyde!burl!ulysses!allegra!princeton!caip!seismo!harvard!husc6!talcott!lotto From: lotto@talcott.UUCP (Jerry Lotto) Newsgroups: net.micro.pc Subject: Re: AT diagnostic information needed Message-ID: <598@talcott.UUCP> Date: Sat, 7-Jun-86 10:00:50 EDT Article-I.D.: talcott.598 Posted: Sat Jun 7 10:00:50 1986 Date-Received: Mon, 9-Jun-86 02:04:33 EDT References: <240@sphinx.UChicago.UUCP> Organization: Harvard Univ. Chem. Dept. Lines: 19 Summary: Error code for AT disk