In article <1992Nov9.222001.28262@cs.wisc.edu> rader@ssec.wisc.edu (Steve Rader) writes: >mar@athena.mit.edu (Mark A. Rosenstein) writes: >|> I've made two different kinds of float switches. The first only cost me >|> a couple of dollars, but wasn't especially reliable and called for a part >|> from Radio Shack that has been discontinued (a mercury tilt switch). >|> >I'm glad this works for 'ya, but if I recall correctly, Grainger's does *not* >offer a 120V rated plastic float switch. I suspect you're using a 12V rated >float switch to switch 120V circuit. I'm not sure what the consequences may >be of using a 12V switch for a 120V circuit... I think you'll at least shorten >the switch's life-time and perhaps even harm your pump. (I do know when I >asked some EE geeks around here 'bout using a 12V switch, they definitely Geeks huh. I suggest you read your granger cat again. The $14 switch I bought is rated up to 220 volts at 30 watts. Because I have a 120 watt pump I did use a relay. In my case I use the switch to prevent tank overfill if the syphon breaks (the float switch is in the tank not the sump). I had this happen and once was enough, fortunetly I was in the next room at the time preventing disaster. My sump holds about 15 gallons so I don't worry about the pump running dry. I also have a float valve that keeps the sump level constant filling it from an external tank. Brian
Technical Details
Message-ID:
<1992Nov10.193146.24267@attain.icd.teradyne.com>Path:
arc1-ca.pugleaf.net!sparky!uunet!ogicse!decwrl!decwrl!netcomsv!attain!picasso.icd.teradyne.com!brianReferences:
<1992Nov3.072949.3924@wvnvms.wvnet.edu> <1992Nov4.161045.17300@athena.mit.edu> <1992Nov9.222001.28262@cs.wisc.edu>Show Full Headers
Complete Article Headers
Path: arc1-ca.pugleaf.net!sparky!uunet!ogicse!decwrl!decwrl!netcomsv!attain!picasso.icd.teradyne.com!brian From: brian@picasso.icd.teradyne.com (Brian Hunter) Newsgroups: sci.aquaria,rec.aquaria,alt.aquaria Subject: Re: Float switch for sump pump Message-ID: <1992Nov10.193146.24267@attain.icd.teradyne.com> Date: 10 Nov 92 19:31:46 GMT Article-I.D.: attain.1992Nov10.193146.24267 References: <1992Nov3.072949.3924@wvnvms.wvnet.edu> <1992Nov4.161045.17300@athena.mit.edu> <1992Nov9.222001.28262@cs.wisc.edu> Sender: usenet@attain.icd.teradyne.com Organization: Teradyne, Inc. Boston MA Lines: 23 Nntp-Posting-Host: picasso.icd.teradyne.com