I would suggest you go back to the fluorescent fixture and check out the different tubes available. There are a lot, and many that have a very soft light. If they are still to harsh use a defuser cover. The installation will be easier, probably cheaper and you won't lose the complete hallway when the 12v supply goes out. "DaveC" <anon@bugus.net> wrote in message news:0001HW.BA977EAD001869E90E6B7920@news.covad.net... > I've been asked to help light a small office building hallway. The > fluorescent lamps are way too harsh for the office workers, and the tenants > favor the overhead QH approach. > > I've looked at the local home centers' lighting departments and see quite a > selection of LV systems using overhead steel cable with 3 hanging reflector > bulbs (with a choice of trim, or not) tapped in at appropriate intervals. > > Price for the above from $70-100us. > > Being encouraged by what I saw, I decided to see what I could build from > scratch. > > As you probably can guess, I'm running into current supply/demand > limitations. Each of the 2 hallways could use about 15 lamps. Lamps are > available in 20 and 50w versions, which at 12v, draw approximately 1.7a and > 4.2a, respectively. I now see why the cost of such a system is mostly for the > supply. > > Looking for a ready-made 12v supply, I find this at Jameco for $70us that > provides 12.5a: > > <http://www.jameco.com/cgi- > bin/ncommerce3/ExecMacro/Jameco/searchResult.d2w/report?sort=BPA&search=1234 22 > > > > This would allow me to run 7 of the 20w lamps, or only 2 of the 50w lamps. > > I can't see buying 2 supplies to run the 15 (well, I guess we could rev that > to 14) lamps in each hall. I seem to be butting up against Ohm's Law. > > Maybe build a simple, unreg'd, analog power supply with massive transformer > and rectifiers for 30A? > > Any other ideas (or links to sites) to help me reach a solution would be > greatly appreciated. > > Thanks, > -- > Dave C > dave+usenet3016@mailblocks.net >
Technical Details
Message-ID:
<v7la8nt93er57c@corp.supernews.com>Path:
arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!newsfeed.stanford.edu!news-spur1.maxwell.syr.edu!news.maxwell.syr.edu!sn-xit-03!sn-xit-01!sn-post-01!supernews.com!corp.supernews.com!not-for-mailReferences:
<0001HW.BA977EAD001869E90E6B7920@news.covad.net>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 112d1e,8548d564104ce958,start X-Google-Attributes: gid112d1e,public X-Google-Thread: 10d137,8548d564104ce958,start X-Google-Attributes: gid10d137,public X-Google-Thread: 103407,8548d564104ce958,start X-Google-Attributes: gid103407,public X-Google-Thread: 107cee,8548d564104ce958,start X-Google-Attributes: gid107cee,public X-Google-ArrivalTime: 2003-03-20 21:54:32 PST Path: arc1-ca.pugleaf.net!archiver1.google.com!news1.google.com!newsfeed.stanford.edu!news-spur1.maxwell.syr.edu!news.maxwell.syr.edu!sn-xit-03!sn-xit-01!sn-post-01!supernews.com!corp.supernews.com!not-for-mail From: "Robert Mercer" <rdmercer@wavecomputers.net> Newsgroups: sci.electronics.design,sci.electronics.misc,alt.engineering.electrical,aus.electronics Subject: Re: Supply for LV lighting application? Date: Thu, 20 Mar 2003 23:48:27 -0600 Organization: Posted via Supernews, http://www.supernews.com Message-ID: <v7la8nt93er57c@corp.supernews.com> References: <0001HW.BA977EAD001869E90E6B7920@news.covad.net> X-Priority: 3 X-MSMail-Priority: Normal X-Newsreader: Microsoft Outlook Express 6.00.2800.1106 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1106 X-Complaints-To: abuse@supernews.com Lines: 60