Article View: sci.electronics.design
Article #2397Re: LED temperature dependence
From: Paul Mathews
Date: Thu, 25 Apr 2002 23:32
Date: Thu, 25 Apr 2002 23:32
42 lines
3019 bytes
3019 bytes
Tony Williams <tonyw@ledelec.demon.co.uk> wrote in message news:<4b2cc6c7e6tonyw@ledelec.demon.co.uk>... > In article <21a524b0.0204250322.19119138@posting.google.com>, > Adam Seychell <aseychell@vet.com.au> wrote: > > > The problem lies in a mismatch in temperature sensitivities between > > the two optical paths. When I touch one leg of the LED with a > > soldering iron tip (1 second) the effect is easily produced. I can > > also see the output takes several seconds to settle after power > > is applied, as if the LED is heating up and stabilizing. I > > suspect the LED is changing its radiation pattern with temperature, > > thus altering relative amounts of light to the feedback and > > measuring photodiode. > > I've been here Adam.... Six weeks of piddling about, > trying to get an absorption meter stabilised. > > I ended up with the LED, stabilising photodiode, > and measuring photodiode mounted in an aluminium > block, stabilised at 35C (+/- a fraction). The > output/input light was via 5mm fibre-optics. > I even had a special bundle made, where the servo > takeoff was a 1% Y-piece off the main transmitting > fibre-optic bundle. > > And still the bleeding thing was not stable enough. > > What caught me out was that the transmission through > the measured medium was itself not stable, being > sensitive to temperature and *tiny* shifts in the > wavelength of the generated light. > > The real answer to the problem is to have two > identical light channels, one as a reference (with a > known absorption), and the other being the measuring > channel. The output is the ratio of the two channels. Hmmm....sounds like my #3 alternative...reference channel must share as many sample channel attributes as possible. Even then, you have to worry about periodic recalibration due to aging and dust accretion...that sort of thing. Paul Mathews
Technical Details
Message-ID:
<ed443a10.0204251532.23d5d682@posting.google.com>Path:
arc1-ca.pugleaf.net!archiver1.google.com!postnews1.google.com!not-for-mailReferences:
<21a524b0.0204231906.329565f6@posting.google.com> <ed443a10.0204240648.678bd1c5@posting.google.com> <21a524b0.0204250322.19119138@posting.google.com> <4b2cc6c7e6tonyw@ledelec.demon.co.uk>Show Full Headers
Complete Article Headers
X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 112d1e,486c871a47283bb X-Google-Attributes: gid112d1e,public X-Google-Thread: 103407,486c871a47283bb X-Google-Attributes: gid103407,public X-Google-ArrivalTime: 2002-04-25 16:32:02 PST Path: arc1-ca.pugleaf.net!archiver1.google.com!postnews1.google.com!not-for-mail From: optoeng@pioneernet.net (Paul Mathews) Newsgroups: sci.electronics.design,aus.electronics Subject: Re: LED temperature dependence Date: 25 Apr 2002 16:32:02 -0700 Organization: http://groups.google.com/ Lines: 42 Message-ID: <ed443a10.0204251532.23d5d682@posting.google.com> References: <21a524b0.0204231906.329565f6@posting.google.com> <ed443a10.0204240648.678bd1c5@posting.google.com> <21a524b0.0204250322.19119138@posting.google.com> <4b2cc6c7e6tonyw@ledelec.demon.co.uk> NNTP-Posting-Host: 4.23.65.179 Content-Type: text/plain; charset=ISO-8859-1 Content-Transfer-Encoding: 8bit X-Trace: posting.google.com 1019777522 19878 127.0.0.1 (25 Apr 2002 23:32:02 GMT) X-Complaints-To: groups-abuse@google.com NNTP-Posting-Date: 25 Apr 2002 23:32:02 GMT